SECTION 2: CIRCUIT REQUIREMENTS
110V Operation
The Model G1022SM, Z and ZF motors are
prewired to operate at 110V. See Figure 5 for a
typical 110V installation.
G1022SM and G1022Z:
Under normal 110V use, the Models G1022SM
and Z motors draw approximately 16 amps. We
recommend a 20 amp circuit breaker or a 20 amp
slow-blow fuse.
G1022ZF:
Under normal 110V use, the Model G1022ZF
Figure 5. Typical 110V 3-prong plug and outlet.
motor draws approximately 17 amps. We recom-
mend a 20 amp circuit breaker or a 20 amp slow-
blow fuse.
The circuit you use should be dedicated, (i.e., the
machine should provide the only draw from that
circuit). If frequent circuit failures occur when
using
this
machine,
contact
our
Service
Department or your local electrical contractor.
Because of the high amperage draw of the Model
G1022 Series when wired for 110V, standard
household circuit wiring may not be of a large
enough gauge. A qualified electrician may need to
install a new circuit with wires capable of handling
a 20 amperage draw. Do not attempt to modify an
existing circuit by replacing the circuit breaker
with one rated for a higher amperage.