Circuit Requirements; Grounding Requirements - Grizzly G0513 Owner's Manual

G0513 series, heavy-duty 17 inch bandsaw
Hide thumbs Also See for G0513:
Table of Contents

Advertisement

Circuit Requirements

These machines are prewired to operate on a 220V power supply circuit that has a verified ground and meet
the 220V operation requirements listed below.
Models G0513, G0513ANV, G0513X2, and G0513X2F can be converted to operate on a 110V power supply
(refer to Voltage Conversion instructions beginning on Page 14) that has a verified ground and meets the
220V operation requirements listed below.
Model Number
Circuit Requirements For 220V Operation:
Nominal Voltage
Cycle
Phase
Power Supply Circuit
Plug/Receptacle
Power Cord
Circuit Requirements For 110V Operation:
Nominal Voltage
Cycle
Phase
Power Supply Circuit
Plug/Receptacle
Power Cord

Grounding Requirements

This machine MUST be grounded. In the event
of certain malfunctions or breakdowns, grounding
reduces the risk of electric shock by providing a
path of least resistance for electric current.
Grounding Requirements for 220V: The plug
specified under "Circuit Requirements for 220V
Operation" on this page has a grounding pin that
must be attached to the equipment-grounding
wire inside the specified power cord. The plug
must only be inserted into a matching recep-
tacle (see Figure 5) that is properly installed and
grounded in accordance with all local codes and
ordinances.
-12-
G0513, G0513ANV, G0513X2, G0513X2F
"S"-Type, 3-Wire, 14 AWG, 300 VAC
110V/120V
60 Hz
Single-Phase
30 Amps
NEMA L5-30
"S"-Type, 3-Wire, 12 AWG, 300 VAC
G0513X2B & G0513X2BF
220V/240V
60 Hz
Single-Phase
15 Amps
NEMA 6-15
GROUNDED
6-15 RECEPTACLE
Current Carrying Prongs
6-15 PLUG
Grounding Pin
Figure 5. Typical 6-15 plug and receptacle.
G0513 Series Bandsaws (Mfd. Since 07/18)
N/A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G0513anvG0513x2bfG0513x2fG0513x2G0513x2b

Table of Contents