Section 5 Specifications; General - Omega OS136A Series User Manual

Miniature low-cost non-contact infrared temperature sensor/transmitter
Hide thumbs Also See for OS136A Series:
Table of Contents

Advertisement

SECTION 5 – SPECIFICATIONS

5.1 - General

Temperature Range
Accuracy:
Repeatability:
Optical Field of View:
Spectral Response:
Response Time:
Emissivity:
Analog Output
Output Load Requirements
Operating Ambient Temperature
Operating Relative Humidity:
Water Flow Rate for OS136-WC:
Air Flow Rate for OS136-WC
Warm up Period:
Thermal Shock:
Air Flow Rate for Air Purge Collar 1 CFM (0.5 liters/sec.)
Transmitter Housing:
Power:
Dimensions:
Weight:
OS136A-1:
OS136A-2:
OS136A-1:
OS136A-2:
MA:
V1:
V2:
K:
MVC:
MVF:
Min. Load (0 to 5 Vdc):
Min. Load (0 to 10 Vdc):
Max. Load (4 to 20 mA):
Min. Load (10 mV/Deg):
Min. Load (K T/C):
No Water Cooling:
With Water Cooling (OS136-WC): 0 to 200ºC (32 to 392ºF)
With Air Cooling (OS136-WC): 0 to 110°C (32 to 230°F)
Specifications
-18 to 204ºC (0 to 400ºF)
149 to 538ºC (300 to 1000ºF)
3% of Rdg or 4.4ºC (8ºF) whichever is greater
3% of Rdg or 5.5ºC (10ºF) whichever is greater
From 185 to 510ºC (365 to 950ºF)
1% of Rdg.
6 to 1 (Distance to Spot Size)
5 to 14 microns
150 msec, 0 to 63% of final value
Fixed at 0.95
4 to 20 mA
0 to 5 Vdc
0 to 10 Vdc
K type Thermocouple, compensated
10 mV/ºC
10 mV/ºF
1 K-Ohms
2 K-Ohms
(Power Supply – 4) / 20 mA
10 K-Ohms
100 K-Ohms
0 to 70ºC (32 to 158ºF)
Less than 95% RH, non-condensing
0.25 GPM, room temperature, minimum
5 CFM (2.4 liters/sec)
1 to 2 minutes
About 30 minutes for 25ºC abrupt
ambient temperature change
Stainless Steel 316, NEMA-4 & IP65 rated
12 to 24 VDC @ 50 mA
19 OD x 89 L mm (0.75 OD x 3.5" L)
0.40 lb (181 g)
5
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Os136a-1Os136a-2