Begin the vent system installation by selecting the type of venting
to be installed and the path that it will take. Verify that clearances
are met throughout the path of the venting system. Determine if the
fireplace is to be vented out the top or out the rear.
NotICE: Some fireplaces cannot be vented out the rear of the
fireplace.
Determine how the vent system will be terminated out the side of
the house or through the roof. Verify clearances for the termination.
*Note: If using three 90° elbows during horizontal termination.
See Figure 30.
The following vent systems are acceptable for use with the DVP36 series fireplaces:
Duravent® Pro 4" - 6 ⅝"
American Metal Products 4" - 6 ⅝"
Selkirk Direct-Temp® 4" - 6 ⅝"
Security Secure Vent® 4" - 6 ⅝"
Excel DV Venting 4" - 6 ⅝"
Page 8

VeNt SYSteM IDeNtIFICAtIoN

Figure 1

SPeCIAL VeNt SYSteMS

MetalFab SureSeal® 4" - 6⅝"
BDM Manufacturing
Olympia VENTIS®
Empire Horizontal Round Termination
Kits - DVVK-4RE, DVVK-4FRE,
DVVK-4FREVS,DVVK-4REVS
When selecting a vent system for use with the fireplace, refer to
the "Special Vent Systems" section in this manual to determine
what systems are acceptable. Check all clearances and venting
components. Identify if any problems existing in the vent system.
Use Figure 22 on page 17 for top venting, or Figure 32 on page
21 for rear venting to eliminate issues after installation. Check pipe
diameter on vent system and fireplace to verify the size is the same.
NotICE: All outer connection joints must be sealed with
aluminum tape, screws or silicone sealant rated above
300°F/149°C. The inner flue joints do not require any sealant.
Special venting components (Duravent)
See Empire Comfort Systems Retail Price List for Duravent
part numbers and pricing.
Special DV Vent Kits
Available from empire Comfort Systems, Inc. Dealers"
Direct-Vent Fireplace Vent Kit - Vertical,
DVVK-4VP
Includes 46DVA-VCH, 46DVA-F6 and 46DVA-
(DVVK-4V)
SC
Direct-Vent Fireplace Vent Kit for Top Vent,
DVVK-4tP
Thru-the-wall, 8 to 11 inch wall thickness,
(DVVK-4T)
Includes 46DVA-HC, 46DVA-E90, 46DVA-09,
46DVA-08A and 46DVA-WT
Direct-Vent Fireplace Vent Kit for Rear Vent, 5
DVVK-4RP
to 7 inch wall thickness, (standard thru-the-wall
(DVVK-4R)
venting) includes 46DVA-06, 46DVA-HC and
46DVA-WT
Direct-Vent Fireplace Vent Kit For Rear
DVVK-4RE
Vent, Thru-the-wall for 5 to 13 3/4 inch wall
thickness.
Direct-Vent Fireplace Vent Kit for Top Vent,
DVVK-4tSP
Thru-the-wall, 5 to 7 inch wall thickness,
(DVVK-RTS)
Includes 46DVA-HC, 46DVA-E90, 46DVA-06
and 46DVA-WT
*DVVK-4FV
Vertical Flex Vent Kit 4" x 7"
*DVVK-4F
Vertical Flex Vent Kit 4" x 7"
VIB6A
Vertical Inlet Baffle Kit For 6 5/8" diameter.
VIB7A
Vertical Inlet Baffle Kit For 7" diameter.
*Empire Flex Vent Kits
Empire Flexvent Kit DVVK-4F
Empire Flexvent Kit DVVK-4FV Vertical
Flex Vent Kit
39358-3-1019

Advertisement

Table of Contents
loading

Table of Contents