ReMote CoNtRoL oPeRAtIoN INStRUCtIoNS
SMARt tHeRMoStAt oPeRAtIoN
The Smart Thermostat function adjusts the flame height in accor-
dance with the difference between the set point temperature and
the actual room temperatures.
As the room temperature gets closer to the set point the Smart
Function will modulate the flame down.
To activate this function, press the THERMOSTAT key until the
word "SMART" appears to the right of the temperature bulb
graphic.
To adjust the set temperature, press the UP or DOWN ARROW
keys until the desired set temperature is displayed on the LCD
screen of the Transmitter.
NotICE: When Smart Thermostat is activated, the manual flame
height adjustment is disabled.
Figure 81 - SMARt Function Icon
Page 58
Figure 82
FAN SPeeD CoNtRoL
The speed of the fan can be controlled by the Proflame system.
The fan speed can be adjusted through six speeds.
To activate this function, use the MODE key Figure 72a to index
to the fan control icon. See Figure 83.
Use the UP/DOWN ARROW keys to turn on, off or adjust fan
speed. See Figures 72a and 84.
A single "beep" will confirm reception of the command.
Figure 83 - Fan Icon
Figure 84 - Fan Speed Control Activated
39358-3-1019