Empire Comfort Systems DVP36FP30N-5 Installation Instructions And Owner's Manual page 19

Direct vent zero clearance gas fireplace heater
Hide thumbs Also See for DVP36FP30N-5:
Table of Contents

Advertisement

VeNtING FIRePLACe - toP (CoNt'D)
MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH
THE WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE
ELBOW OFF TOP OF FIREPLACE
HARD eLBoW DIMeNSIoNS
FIRePLACe
SeRIeS
"A"
43-1/2"
DVP36FP
(1105mm)
FLeX PIPe 90 DeGRee BeND
FIRePLACe
SeRIeS
"A"
45"
DVP36FP
(1143mm)
Positioning the Fireplace
Determine the exact position of the appliance so the direct vent
termination will be centered (if possible) between two studs. This
will avoid any extra framing. All vent kit pipes should be assembled
on the unit after the unit is moved into the final position.
Cutting the Hole
After the fireplace has been positioned in its permanent location,
the hole through the exterior wall of the house can be cut. This hole
must be 11" (280mm) high x 9-1/8" (232mm) wide with its center line
determined by the amount of vertical rise and horizontal run of the
termination. See Figures 26 and 39. When locating the hole it must
be noted that the bottom of the cap must be 12" (305mm) above the
ground level, and top of the cap must be no less than 18" (457mm)
below a combustible projection, and no closer than 9" (229mm) to
any wall running parallel to vent termination. See Figure 27.
39358-3-1019
Figure 26
"B"
4-1/2"
6-1/2"
(114mm)
(165mm)
"B"
4-1/2"
6-1/2"
(114mm)
(165mm)
"C"
"C"
Figure 27
Figure 28
Page 19