5. CONNECTING THE POWER PLUG

CAUTION
:
To prevent possible accidents caused by leakage or dielectric strength, an appropriate power plug
shall be installed by a person who has an expert knowledge of electricity. Be sure to connect the pow-
er plug to the receptacle that is well grounded.
Connection of the power plug to the power depends on the specifications of the product. Adjust the power
plug to the power specifications to connect.
In case of the product of single-phase, 220 to 240V specifications :
Connect the sky-blue and brown wires of the power cord to the power terminal (AC220 to 240V) and the
yellow/green wire to the ground (earth) terminal respectively.
In case of the product of 3-phase, 200 to 240V specifications :
Connect the red, white and black wires of the power cord to the power terminal (AC200 to 240V) and
the yellow/green wire to the ground (earth) terminal respectively.
In case of the product with the optional high voltage transformer (with SA-128) :
Connect the black wires (3 pieces) of the power cord to the power terminal (AC380 to 415V) and the
yellow/green wire to the ground (earth) terminal respectively.
It is possible to connect to 380/400/415V by setting of the input tap of transformer (standard setting at
the time of delivery : 380V).
This product performs operation by the single-phase connection for 3-phasse 380/400/415V.
[ Caution when changing the power source of the high voltage optional transformer ]
When using high voltage optional transformer ❶ with
the input voltage of 400V or 415V, it is necessary to
replace input power source cord ❷ of high voltage
optional transformer ❶ . Change power source input
cord ❷ (sky blue) that is connected to 380V to the
connection of 400V or 415V.
To prevent accidents, perform the work
after leaving the sewing machine alone
more than 4 minutes in the state that
the power switch is turned OFF and the
power cord is drawn out.
High voltage optional transformer ❶ is set on the
rear side of the table.
When performing changeover of voltage, remove
transformer box ❹ after removing top cover ❸ .
− 6 −