Installation

Reflective Sensor

The reflective sensor is used to detect notched material as well as to detect
black marks on the back of label stock. There is a clear label covering the
reflective sensor. (When operating in Brady mode, the LCD display will show
sensor placement information (Figure 14, 2).)

Brady Mode

1. The LCD will indicate Brady mode (Figure 14, 1) and show sensor
placement information (Figure 14, 2).
2. Open the cover (Figure 1, 9) lower the control panel (Figure 1, 17) , and
press the green print module release button (Figure 1, 15).
3. Adjust the sensor knob (Figure 14, 4) with a pointed tool to the position
displayed on the LCD (Figure 14, 2).
4. Lower the Print Module (Figure 1, 14). Lift the control panel
(Figure 1, 17) and press firmly until the panel clicks into position.
5. Close the cover (Figure 1, 9).

Standard Mode

1. Open the cover (Figure 1, 9) lower the control panel (Figure 1, 17) , and
press the green print module release button (Figure 1, 15).
2. Adjust the sensor knob (Figure 14, 4) with a pointed tool until the sensor
inside the sensor window (Figure 14, 3) is aligned with the edge of the
labels. If the label material is notched, the sensor must be aligned with the
notch.
3. Lower the print module (Figure 1, 14). Lift the control panel
(Figure 1, 17) and press firmly until the panel clicks into position.
4. Close the cover (Figure 1, 9).