Omron V680S-HMD64-EIP User Manual page 62

Ethernet/ip reader/writer
Hide thumbs Also See for V680S-HMD64-EIP:
Table of Contents

Advertisement

Section 3
Names and Functions of Components
 Operation Indicators
RUN
Status
Lit green
Lighting while the Reader/Writer is operating normally.
Flashing
Flashes during operation in Safe Mode. (Flashes at 1-s intervals.)
green
Flashing
The indicator will flash quickly in the following cases. (Flashes at 200-ms intervals.)
green
• During Reader/Writer initialization
quickly
• While the Reader/Writer is in Run Mode and is waiting to establish tag data links as the originator
Lit yellow
Lights yellow while the Reader/Writer is operating in Slave Mode.
Flashing
Flashes quickly while the Reader/Writer is in Slave Mode and is waiting to establish tag data links as the originator.
yellow
quickly
Not lit
Turn off when power is not supplied.
 RF
Status
Lit yellow
Lighting during communication for RF Tag.
Not lit
Turn off when not in communication with no error.
 NORM/ERR
The NORM/ERR indicator shows the result of communications with an RF Tag.
Status
Lit green
Lights once when processing a communications command or another command from the host device is completed normally.
When communication diagnostic is enabled, this indicator will flash once each time a stable communication is detected.
Lit yellow
When communication diagnostic is enabled, this indicator will flash once each time an unstable communication is detected.
Flashing
Flashes quickly when a timeout is detected during tag data links. (A timeout occurs when tag data from the originator is not
yellow
received within the time specified for the timeout value.)
quickly
Lit red
Lights once when processing a communications command or another command from the host device ends in an error. It
continues to light if a system error occurred.
Flashing
Flash when recoverable error occurs. (Configuration memory error, or Control signal wiring mistake, etc.)
red
Flashing
The indicator will flash irregularly in the following cases. (It will repeatedly flash twice for 100 ms at 1-s intervals.)
red
• When the same IP address is detected for two different devices on the network at startup
irregularly
• When an error occurs when getting an IP address from the BOOTP server at startup (The BOOTP server does not respond.
The IP address from the BOOTP server to set in the Reader/Writer is illegal.)
Not lit
Turn off when the standby state.
 LINK/ACT
Status
Lit
green
Lighting during linking normally.
Flashing
Flash during detects a carrier.
green
Not lit
Turn off when the ethernet cable is not connected.
Refer to Errors and Indicator Status in Section 9 Troubleshooting for information of Error content of the operation indicator
p.216
RFID System
60
User's Manual
(EtherNet/IP
TM
)
Meaning
Meaning
Meaning
Meaning

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680s seriesV680s-hmd63-eipV680 seriesV680s-hmd66-eip

Table of Contents