Omron V680S-HMD64-EIP User Manual page 171

Ethernet/ip reader/writer
Hide thumbs Also See for V680S-HMD64-EIP:
Table of Contents

Advertisement

 Execution Example
Setting the Multi-Reader/Writer Mode to Field Extension Mode, the Number of Slave Reader/Writers to
3, and the IP Addresses of Slaves No. 1, No. 2, and No. 3 to 192.168.1.201, 192.168.1.202, and
192.168.1.203, Respectively
Command Area
Memory offset
Data name
bit15-12 bit11-8
+1
CmdCode
+2
CmdParam1
+3
CmdParam2
+4
CmdData[0-1]
+5
CmdData[2-3]
+6
CmdData[4-5]
+7
CmdData[6-7]
C
+8
CmdData[8-9]
+9
CmdData[10-11]
C
+10
CmdData[12-13]
+11
CmdData[14-15]
C
+12
CmdData[16-17]
+13
CmdData[18-19]
+14
CmdData[20-21]
+15
CmdData[22-23]
+16
CmdData[24-25]
+17
CmdData[26-27]
+18
CmdData[28-29]
+19
CmdData[30-31]
bit7-4
bit3-0
1
0
0
3
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
3
0
1
C
9
IP address of Slave Reader/Writer No. 1
0
A
8
0
1
C
A
IP address of Slave Reader/Writer No. 2
0
A
8
0
1
C
B
0
A
8
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
IP address of Slave Reader/Writer No. 6
0
0
0
0
0
0
0
0
IP address of Slave Reader/Writer No. 7
0
0
0
0
Host Communications Specifications
Response Area
Memory offset
Data name
bit15-12 bit11-8
+1
ErrCode
0
+2
RespInfo1
0
+3
RespInfo2
0
Section 7
bit7-4
bit3-0
0
0
0
0
0
0
0
0
0
RFID System
169
User's Manual
(EtherNet/IP
TM
)

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680s seriesV680s-hmd63-eipV680 seriesV680s-hmd66-eip

Table of Contents