Omron V680S-HMD64-EIP User Manual page 55

Ethernet/ip reader/writer
Hide thumbs Also See for V680S-HMD64-EIP:
Table of Contents

Advertisement

 The plural Reader/Writer's are connected to the Host device (e.g., PLC)
Reader/Writer
(V680S-HMD6 -EIP)
RF Tag
(V680 Series and V680S Series)
Ethernet Cable (Max. length: 100 m)
(Recommended: XS5W-T42 - MC-K from OMRON)
Power Cable
(Recommended: XS5F-D42 - 80-F from OMRON)
Connect the Ethernet Cable to a host device (e.g., Switching Hub or PLC) that supports STP and ground the host device to
100 Ω or less.
Always use a Switching Hub on any network where tag data links are used.
If you use a repeater hub on a network on which EtherNet/IP tag data links (cyclic communications) are used, the network
communications load will increase causing frequent collisions and unstable communications.
Use a host device (PLC) that can set connections as the originator (i.e., the side that requests opening a communications line for
tag data links).
Reader/Writer
(V680S-HMD6 -EIP)
RF Tag
(V680 Series and V680S Series)
Ethernet Cable (Max. length: 100 m)
(Recommended: XS5W-T42 - MC-K from OMRON)
Power Cable
(Recommended: XS5F-D42 - 80-F from OMRON)
24-VDC power supply
System Configuration
24-VDC power supply
Section 2
Host device
(e.g., PLC)
Ethernet Cable
RFID System
53
User's Manual
(EtherNet/IP
TM
)