Section 6
Functions
11.
The following dialog box is displayed after reconnecting to the Reader/Writer. Click the OK Button.
When re-connection goes wrong and an error message is displayed, check connection with the Reader/Writer and
reboot a Web browser.
After re-connection, displays the "Status" window.
12.
When the Master Reader/Writer is restarted, group registration processing is automatically performed
for the registered Slave Reader/Writers.
If the Master Reader/Writer cannot establish communications with a registered Slave Reader/Writer (e.g., due to an
incorrect IP address or because the Slave Reader/Writer is not started), the ERROR indicator (red) on the Master
Reader/Writer will flash at 1-s intervals.
13.
You can confirm when communications have been established with all of the slave Reader/Writer from
the Multi-Reader/Writer Setting View of the Web browser operation window.
14.
The RUN indicator will light yellow on Reader/Writers that are operating as slave Reader/Writers. The
indicator on the master Reader/Writer will remain lit green.
15.
This concludes the procedure to set Field Extension Mode. You can now use READ DATA or WRITE
DATA commands from the host controller for the Master Reader/Writer to perform linked operation of
multiple Reader/Writers.
RFID System
128
User's Manual
(EtherNet/IP
TM
)