Section 2
System Configuration
 The computer is connected to monitor the results of communications diagnostics
Reader/Writer
(V680S-HMD6 -EIP)
(V680 Series and V680S Series)
Connect the Ethernet Cable to a host device (e.g., Switching Hub or PLC) that supports STP and ground the host device to
100 Ω or less.
Always use a Switching Hub on any network where tag data links are used.
If you use a repeater hub on a network on which EtherNet/IP tag data links (cyclic communications) are used, the network
communications load will increase causing frequent collisions and unstable communications.
Use a host device (PLC) that can set connections as the originator (i.e., the side that requests opening a communications line for
tag data links).
RFID System
54
User's Manual
(EtherNet/IP
TM
)
RF Tag
Ethernet Cable
Ethernet Cable (Max. length: 100 m)
(Recommended: XS5W-T42 - MC-K from OMRON)
Power Cable
(Recommended: XS5F-D42 - 80-F from OMRON)
The system requirements to use the Web browser are as follows:
Windows 8.1/Windows 10
Internet Explorer 11/Microsoft Edge/Google Chrome
For details, refer to Section 8 Web Browser Interface.
p.187
Computer to monitor the
Host device
results of communications
(e.g., PLC)
diagnostics
Switching Hub
(Recommended: W4S1-05C Switching Hub
from OMRON)
24-VDC power supply
Computer