Replace Circuit Breaker - Graco Reactor 3 Repair And Parts Manual

Proportioning systems
Hide thumbs Also See for Reactor 3:
Table of Contents

Advertisement

Repair

Replace Circuit Breaker

1. Follow Before Beginning Repair on page 22.
2. Use an ohmmeter to check continuity across the
circuit breaker (top to bottom). If there is no
continuity, trip the breaker, then reset and retest it.
If there is still no continuity, replace the breaker:
a. Refer to the circuit breaker table in Electrical
Schematics on page 69.
b. Turn the main power switch (MP) off.
30
c. Loosen the two screws connecting the wires
d. Pull the locking tab out 1/4 in. (6 mm) and pull
Ref.
CB1
CB2
CB3
CB4
CB5
MP
and bus bar to the circuit breaker that will be
replaced, then disconnect the wires.
the circuit breaker away from the din rail. Install
the new circuit breaker. Insert the wires and
tighten down all screws.
Circuit Breakers
Size
Component
40A
A (ISO) Heat
40A
B (RES) Heat
40A
Hose Transformer Primary
50A
Hose Heat
20A
Motor
ti41006a
3A8501A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents