Technical Specifications

Reactor E-XP2

Reactor 3 Proportioning Systems, E-XP2
Maximum Fluid Working Pressure
Maximum Fluid Temperature
Maximum Flow Rate
Maximum Heated Hose Length
Approximate Output Per Cycle (A+B)
Operating Ambient Temperature Range
Fluid Inlets
Fluid Outlet – A
Fluid Outlet – B
Fluid Circulation Port Size
Fluid Circulation
Port Maximum Pressure
Wetted Parts
Maximum Fluid Inlet Pressure
Line Voltage Requirement
200–240 VAC, 1–ph, 50/60 Hz
200–240 VAC, 3–ph DELTA, 50/60 Hz
350-415 VAC, 3-ph WYE, 50/60 Hz
Sound Pressure: Measured per ISO-9614-2
Measured from 3.1 ft (1 m) @ 3000 psi
(21 MPa, 207 bar), 1 gpm (11.4 lpm)
Sound Power:
Measured from 3.1 ft (1 m) @ 3000 psi
(21 MPa, 207 bar), 1 gpm (11.4 lpm)
Dimensions:
Width
Depth
Height
Weight:
Elite kW
Notes:
All trademarks or registered trademarks are the property of their respective owners.
80
U.S.
3500 psi
180 °F
2.1 gpm
320 ft
0.0203 gal
20 °F to 120 °F
#8 (1/2 in.) JIC, with #5 (5/16 in.) JIC adapter
#10 (5/8 in.) JIC, with #6 (3/8 in.) JIC adapter
250 psi
Aluminum, stainless steel, zinc-plated carbon steel, nickel-plated carbon steel, brass,
tungsten carbide, chrome, chemically resistant o-rings, PTFE, acetal, ultra high
Pro and Elite
Standard
Models
Models
400 psi
26.8 in.
15 in.
56.5 in.
330 lb
3/4 npt(f)
1/4 nps(m)
molecule weight polyethylene
Standard
Models
600 psi
27.6 bar, 2.76 MPa
79.6 dBA
86.6 dBA
Metric
241 bar, 24.1 MPa
82.2 °C
7.9 lpm
97.5 m
77.1 cc
-7 °C to 49 °C
17 bar, 1.7 MPa
Pro and Elite
Models
41.3 bar, 4.13 MPa
68 cm
38 cm
144 cm
149.7 kg
3A8501A