Replace Transformer - Graco Reactor 3 Repair And Parts Manual

Proportioning systems
Hide thumbs Also See for Reactor 3:
Table of Contents

Advertisement

Repair

Replace Transformer

1. Follow Shutdown on page 20.
2. Remove bolts (24) and covers (57, 58).
76
9
38
22
8
42
3. Remove transformer cover (9).
4. Disconnect transformer connections from terminal
blocks. Connections are labeled: 1, 2, 3, and 4.
5. Remove transformer (8).
6. Install transformer (8) in reverse order.
24
57
58
ti40201a
3A8501A

Hide quick links: