Top Vent Configuration with Horizontal Termination
•
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
•
Up to four elbows (45° or 90°) may be used.
•
Use 205mm diameter vent and the Amerivent Cowl (4DHC)
•
Only one horizontal elbow may be used.
21' (max)
6.4m (max)
20 feet
6m
15 feet
4.5m
10 feet
3m
5 feet
1.5m
0 feet
0m
This is considered a horizontal
This is considered a horizontal
elbow (it does not matter
elbow (it does not matter
whether it turns right or left). It
whether it turns right or left).
may be a 90° or 45° elbow.
It may be a 90° or 45° elbow.
© Travis Industries
Installation
(for qualified installers only)
Exhaust Restrictor # 4
Intake Restrictor # 2
Diffuser Position # 2
H2
H1
Exhaust Restrictor # 6
Intake Restrictor # 2
Diffuser Position # 2
Exhaust Restrictor # 2
Intake Restrictor # 1 (stock)
Diffuser Position # 1 (stock)
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is considered a
vertical elbow
4070620
27
21' (max)
6.4m (max)
20 feet
6m
15 feet
4.5m
10 feet
3m
5 feet
1.5m
0 feet
0m
100-01199_000