Optional Wall Thermostat; Final Check - FPI Hampton H15U-NG Owners & Installation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

Optional Wall Thermostat/Remote
Control
Part #910-407 Basic Wall Thermostat
Part #910-404/P Programmable Wall Thermostat
Part #910-399 Remote Control
A wall thermostat or remote control may be installed if desired.
Connect the wires as per the wiring diagrams. Note that the wires
are connected to the "TH" on the gas valve. Use table below to
determine the maximum wire length:
Note: Preferable if the thermostat is installed on an interior wall.
Hampton
®
offers an optional programmable thermostat but any
250-750 millivolt rated non-anticipator type thermostat that is CSA,
ULC or UL approved may be used.
CAUTION
Do not wire millivolt
wall thermostat wires
to 120V wire.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Max. Length
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
Hampton® H15U-NG/LP Direct Vent Freestanding Gas Stove
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.

Final Check

Before leaving this unit with the customer, the installer must
ensure that the appliance is firing correctly. This includes:
1) Clocking the appliance to ensure the correct firing rate (rate
noted on label) at 15 minutes.
2) If required, adjusting the primary air to ensure that the flame
does not carbon. First allow the unit to burn for 15 min. to
stabilize.
3) Check for proper draft.
CAUTION
Any alteration to the product that causes soot-
ing or carboning that results in damage to the
exterior facia is not the responsibility of the
manufacturer.