installation

Dura-Vent Termination Kit - Planning Your Dura-Vent Installation

There are two basic types of Dura-Vent Direct
Vent System installations: horizontal termination
and vertical termination. Confirm the maximum
horizontal run and maximum vertical rise from
the diagrams in the "Rigid Pipe Venting Sys-
tems" section.
When planning your installation, it will be nec-
essary to select the proper length of vent pipe
for your particular requirements. For horizontal
installations, determine the minimum clearance
from the rear of the unit to the wall. It is also
important to note the wall thickness. (The wall
thimble is suitable for 2 x 4 or 2 x 6 wall construc-
tion.) Select the amount of vertical rise desired
for "vertical-to-horizontal" type installations.
Dura-Vent Vertical
Termination Installation
Vertical
Terminal
Storm Collar
Flashing
(0-12/6-12)
Ceiling
Cathedral
Firestop
Ceiling
Support Box
Round Support
Box/Wall Thimble
Pipe Length
28
Warning: Always maintain required
clearances (air spaces) to nearby
combustibles to prevent a fire
hazard. Do not fill air spaces with
insulation.
The minimum clearance requirements between
the outer wall of the vent pipe and nearby com-
bustible surfaces is 1-1/4 inch. Be sure to check
the vent termination clearance requirements
from decks, windows, soffits, gas regulators, air
supply inlets and public walkways as specified
in the "Exterior Vent Terminal Locations" section
and in your local building codes.
(D)
Vertical Termination Kit
*Round Support
Box/Wall Thimble
Adj.Pipe Length
o
*90 Elbow
Pipe Length
1 90
1 Round Support Box/Wall Thimble Cover
1 Horiz. Sq. Term. Cap
The FPI AstroCap
Simpson Dura-Vent® and Direct Vent.
The FPI AstroCap
Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson
Dura-Vent Co. Inc.
Dura-Vent Horizontal
Termination Installation
(A)
*Horizontal Termination Kit
Part # 46DVA-KHA
*Horizontal
Termination Cap
Vinyl Siding
Standoff (Optional)
Wall Thimble
Basic
Horizontal Kit
Part # 46DVA-KHA
Elbow
o
is certified for installations using FPI venting systems as well as
TM
TM
is a proprietary trademark of FPI Fireplace Products International Ltd.
Hampton® H15U-NG/LP Direct Vent Freestanding Gas Stove
To determine the length of vent pipe required
for vertical installations, measure the distance
from the unit flue outlet to the ceiling, the ceiling
thickness, the vertical rise in an attic or second
storey, and allow for sufficient vertical height
above the roof line.
For multi-storey applications, fire stops are
required at each floor level. If an offset is
needed, additional pipe, elbows and supports
will be required.
Do not exceed the maximum number of elbows.
One 90
o
for horizontal terminations and two 45
for vertical termination.
You will require the following components with
your new Direct Vent Freestanding Gas Stove.
Please review your product to make sure you
have everything you need. In the event that
you are missing any part, contact your dealer.
Note: These are the minimum pieces re-
quired. Other parts may be required
for your particular installation. See
above for a list of vent parts.
Alternate Horizontal
Termination Caps
AstroCap
Part# 946-523/P
Alternate
Horizontal
Riser Vent
Terminal
Part# 640-530/P
o