THE KENSINGTON
3-panel Door
Installation
1) Install the Sub-Frame by hooking the top
fl ange onto the top of the Glass Door and
swing the Sub-Frame towards the unit. Pull
out the hooks which already secure the
Glass Door and place them thru the holes
in the bottom of the Sub-Frame to secure
both the Glass Door and Sub-Frame in place
together.
Sub-Frame
Hook
2) Mount the 3-panel Screen Door / Frame
Assembly to the fl ange on Sub-Frame,
ensuring to line-up holes. Secure using the
4 screws provided.
U32-4 FPI Direct Vent Gas Insert
®
OPTIONAL WALL
THERMOSTAT
A wall thermostat may be installed if desired,
follow the wiring diagram below. FPI offers an
optional programmable thermostat but any
250-750 millivolt rated non-anticipator type
thermostat that is CSA, ULC or UL approved
may be used.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
Glass Door
14 GA.
Sub-Frame
16 GA.
18 GA.
20 GA.
22 GA.
Do not connect the millivolt wall
thermostat wires
to the 120V wires.
OPTIONAL REMOTE
CONTROL
Use the FPI Remote Control Kit approved for
this unit. Use of other systems may void your
warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
1) Choose a convenient location on the wall
to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fi replace to
that location. Use Thermostat Wire Table.
2) Connect the wires as per the wiring diagrams
below.
Do not connect the millivolt
remote control wires for
to the 120V wires.
3) Install 3 AAA alkaline batteries in transmitter
and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.
Max. Length
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.
CAUTION
CAUTION
INSTALLATION

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly. This includes:
1) Clocking the appliance to ensure the
correct fi ring rate (rate noted on label) at
15 minutes.
2) If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow
the unit to burn for 15 min. to stabilize.
3) Check for proper draft.
CAUTION
Any alteration to the product that
causes sooting or carboning that
results in damage to the exterior
facia is not the responsibility of
the manufacturer.