Table Of Contents - Siemens ARCADIS Varic Start-Up

Hide thumbs Also See for ARCADIS Varic:
Table of Contents

Advertisement

Table of Contents

1-
0Table of Contents
1 _______ General information______________________________________________ 5
Additionally required documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Tools, aids (partially for IQ test) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Note on the log book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Notes on adapting the power plug to local conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Note on the power connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Notes on equivalent leakage current measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Applicability and regulations for regional companies . . . . . . . . . . . . . . . . . . . . . . . . 10
Initial measured value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Repeat measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Switching the system to be free of voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Main system control board D1 and power board D2. . . . . . . . . . . . . . . . . . . . . . . . . 13
Monitor cart, monitors and image system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2 _______ General Start-up________________________________________________ 14
Power connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Measuring the line voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Adapting the line voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Measuring the system leakage current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Measuring arrangements for system leakage current with tester VDE 0751 October
2001 (preferred measuring method) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Measuring arrangements for system leakage current with tester VDE 0751 October
1990 (e.g. Bender tester) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Function check of the emergency stop switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Checking the temperature indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Function checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Testing the ground wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Functional test of C-arm lift movement and parking brakes . . . . . . . . . . . . . . . . . . . . . . 22
3 _______ Specific system settings_________________________________________ 23
System configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Service login: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Customer address configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Main system configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Country-specific adaptation of the maximum tube current . . . . . . . . . . . . . . . . . . . . 30
Backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
4 _______ Final Work Steps _______________________________________________ 37
Paper printer (optional). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Sony printer LPR-1000MD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Siemens AG
Medical Solutions
SPR2-310.815.01.05.02
02.05
Page 3 of 48