2
Product information
2.4

Type plate

Pos.
Description
1
Type
2
Serial number
3
Useful capacity (overall)
4
Standby heat loss
5
Volume heated by immersion heater
6
Year of manufacture
7
Corrosion protection
8
Maximum DHW temperature
9
Maximum heating water flow temperature
10
Maximum solar flow temperature
11
Electrical power cable
12
Continuous output
13
Volumetric flow rate to reach continuous output
14
Volume with 40 °C draw-off temperature heated by immersion
heater
15
Maximum operating pressure on the domestic water side
16
Maximum design pressure (cold water)
17
Maximum operating pressure of heating water
18
Maximum operating pressure, solar side
19
Maximum operating pressure on the domestic water side
(CH only)
20
Maximum test pressure on the domestic water side (CH only)
21
Maximum DHW temperature with immersion heater
Table 49 Type plate
2.5

Tech data

Dimensions and specifications
Pressure drop diagram
General description
Tilt height
Minimum room height for anode
replacement
Connection size, DHW
Connection size, cold water
Connection size, circulation
Inside diameter of test point, solar
cylinder temperature sensor
Inner diameter, test point, cylinder
temperature sensor
Inside diameter of handhole
Cylinder capacity
Useful capacity (overall)
Useful capacity (excl. solar thermal
heating)
1)
Usable DHW volume
with DHW outlet
2)
temperature
:
45 °C
40 °C
44
Unit
SM310.5 E
 Fig. 2,
-
page 67
 Fig. 3/ 4,
-
page 68
mm
1953
mm
2100
DN
R1"
DN
R1"
DN
R¾ "
mm
19.5
mm
19.5
mm
120
l
287
l
119
l
170
l
198
Standby heat loss (24 h) in accordance
3)
with DIN 4753 Part 8
Maximum flow rate at cold water inlet
Maximum DHW temperature
Maximum operating pressure, potable
water
Upper heat exchanger
Content
Surface area
Rating code N
according to DIN 4708
L
Continuous output (at 80 °C flow
temperature, 45 °C DHW outlet
temperature and 10 °C cold water
temperature)
Heating water volumetric flow rate
Heat-up time with 31.5 kW rated output,
10 °C cold water temperature, 60 °C
domestic hot water temperature
Maximum heating water temperature
Maximum operating pressure of heating
water
Connection size, heating water
Bottom heat exchanger (solar)
Content
Surface area
Maximum heating water temperature
Maximum operating pressure of heating
water
Connection size, solar
1) Without solar thermal heating or recharging; set cylinder temperature 60 °C.
2) Mixed water at draw-off point (at 10 °C cold water temperature).
3) Excluding distribution losses outside the cylinder.
4) The rating code N
=1 according to DIN 4708 for 3.5 persons, standard bath tub
L
and kitchen sink. Temperatures: cylinder 60 °C, DHW outlet temperature 45 °C
and cold water 10 °C. Measured at max. heat output. If the heat output is
reduced, N
becomes smaller.
L
Table 50 Tech data
2.6

Product data for energy consumption

The following product data satisfy the requirements of the EU
Regulations No. 811/2013 and No. 812/2013 supplementing EU
Regulation 2017/1369.
Manufacturers who implement these guidelines and state the ErP values
are permitted to use the "CE" mark.
Product
Product
number
type
volume (V)
8732928457 SM310.5 E
W-B
8732928458 SM310.5 E
S-B
Table 51 Product data for energy consumption
Logalux – 6721829955 (2020/12)
Unit
SM310.5 E
kWh/24 h
1.56
l/min
16
°C
95
bar
10
(positive)
l
5.7
2
m
0.85
4)
N
1.6
L
kW
25.8
l/min
634
l/h
2600
min
28
°C
160
bar
16
(positive)
DN
R1"
l
8.5
2
m
1.26
°C
160
bar
16
(positive)
DN
R1"
Cylinder
Heat
Energy
retention
efficiency
loss (S)
class for
DHW
treatment
287,0 l
65,1 W
B
287,0 l
65,1 W
B