Material
1 µm
Aluminum
Unoxidized
0.1-0.2
Oxidized
0.4
Alloy
A3003,
Oxidized
Roughened
0.2-0.8
Polished
0.1-0.2
Brass
Polished
0.1-0.3
Burnished
Oxidized
0.6
Chromium
0.4
Oxidized
Copper
Polished
Roughened
Oxidized
0.2-0.8
Gold
0.3
Haynes
Alloy
0.5-0.9
Inconel
Oxidized
0.4-0.9
Sandblasted
0.3-0.4
polished
0.2-0.5
Iron
Oxidized
0.4-0.8
Unoxidized
0.35
Rusted
Molten
0.35
Iron, Cast
Oxidized
0.7-0.9
Unoxidized
0.35
Molten
0.35
Iron, Wrought
Dull
0.9
Lead
Polished
0.35
Rough
0.65
Oxidized
Magnesium
0.3-0.8
Mercury
Molybdenum
Oxidized
0.5-0.9
Unoxidized
0.25-0.35
Table 9-1: Typical Emissivity Values for Metals
1.6 µm
2.3 µm
0.02-0.2
0.02-0.2
0.4
0.2-0.4
0.4
0.4
0.2-0.6
0.2-0.6
0.02-0.1
0.02-0.1
0.01-0.05
0.01-0.05
0.4
0.6
0.6
0.4
0.05-0.3
0.03
0.03
0.05-0.2
0.05-0.2
0.2-0.9
0.7-0.9
0.01-0.1
0.01-0.1
0.6-0.9
0.6-0.9
0.6-0.9
0.6-0.9
0.3-0.6
0.3-0.6
0.25
0.25
0.5-0.8
0.7-0.9
0.1-0.3
0.1-0.3
0.6-0.9
0.6-0.9
0.4-0.6
0.4-0.6
0.7-0.9
0.7-0.9
0.3
0.1-0.3
0.3-0.4
0.3-0.4
0.9
0.95
0.05-0.2
0.05-0.2
0.6
0.5
0.3-0.7
0.3-0.7
0.05-0.3
0.05-0.2
0.05-0.15
0.05-0.15
0.4-0.9
0.4-0.9
0.1-0.35
0.1-0.3
Metals
Emissivity
Appendix
9
Typical Emissivity Values
63