MP Series
Users Manual, Rev. 1.0, Apr 2021
5.8 Power Supply
The linescanner requires a nominal 24 VDC power supply, 18 VDC minimum. To insure that sufficient voltage is
supplied to the linescanner, it is necessary to define the gage and the length of the power cable to determine the
resistance and the voltage drop. The maximum current draw of the linescanner is 1 A.
The following table shows typical parameters from shielded 2 wire copper cables and the maximum recommended
cable length.
Table 5-3: Maximum allowed Cable Length from a 24 VDC Power Supply to the Linescanner
The linescanner is equipped with an electronic fuse to prevent damage from voltage spikes greater than 36 V on
power or signal lines. If the fuse circuit switches the power off, disconnect the power line for several seconds and
turn power on again.
Power supply cables offered by the manufacturer can be found as electrical accessories, see section 7.7
Supply Cable
A power supply offered by the manufacturer can be found as electrical accessories, see section 7.9
DIN Rail
(A-PS-DIN-24V), page 53.
32
Cable gauge
Resistance per m
0.5 mm²
0.75 mm²
1.0 mm²
1.5 mm²
0.031 /yd
0.56 mm² (AWG 20)
0.021 /yd
0.82 mm² (AWG 18)
0.014 /yd
1.31 mm² (AWG 16)
0.008 /yd
2.08 mm² (AWG 14)
(A-CB-xx-PS-xx), page 51.
Voltage drop per m at 1 A
(1 wire)
(2 wire)
0.040 /m
0.080 V/m
0.027 /m
0.054 V/m
0.020 /m
0.040 V/m
0.014 /m
0.028 V/m
0.062 V/yd
0.042 V/yd
0.027 V/yd
0.016 V/yd
Max. cable length
75 m
111 m
150 m
214 m
289 ft
427 ft
656 ft
1093 ft
Power Supply
Power