7.5 Thermostat (A-MP-THERM)

The thermostat is an accessory which helps keep the housing temperature over the dew point thereby avoiding
damage due to condensed water in the interior of the housing. The thermostat needs no further electrical
installation.
When ordering a thermostat, the shipment contains the following parts:
thermostat, already mounted with one regulation valve, one conduit coupling ½", two thread adapter ½"
to ⅛", two fittings ⅛"
external sensitive element for the thermostat, 2 m (6.6 ft) capillary tube length
mounting block for external sensitive element
2x hex screws M6x16
2x hex screws M3x8
5 m (16.4 ft) cooling hose, PA 8x1, max. pressure 12 bar (174 PSI) at 70°C (158°F)
For the thermostat, the following accessories are available:
Water Flow Regulator (A-TJ-WFR)
Air Flow Regulator (A-TJ-AFR)
Installation:
Before mounting the mounting block, ensure that the mating surface is completely clean, Fix the mounting
block either on the upper or on the lower side of the scanner's housing using the supplied M6x16 hex
screws.
Mount the thermostat close to the scanner within a distance of 1.5 m (4.9 ft).
Cut the cooling hose to lengths according to your needs, see figure above.
48

Figure 7-3: Installation of the Thermostat

Mounting block
Thermostat
Conduit
coupling
Regulation valve
External temperature sensor
Thread adapter
Fitting
Hose
Flow in