Tube Fittings (A-Mp-Fs-Xxx); Installation Of The Tube Fittings - Fluke MP Series Abridged User Manual

Infrared linescanner
Table of Contents

Advertisement

MP Series
Users Manual, Rev. 1.0, Apr 2021

7.4 Tube Fittings (A-MP-FS-xxx)

Description:
The tube fittings are available in two versions:
A-MP-FS-ISO with ISO threads
A-MP-FS-NPT with NPT threads

7.4.1 Installation of the Tube Fittings

The following steps explain the installation of the tube fittings to the stainless steel cooling tubes of the linescanner.
7
Illustrations: © Swagelok
46
4x tube fittings - female adapter union (connects 6 mm outer diameter tube to conical thread
Rc 1/8" (ISO7/1)) or 6 mm outer diameter tube to conical thread 1/8" NPT
Insert tubing into the Swagelok tube fitting.
Make sure that the tubing rests firmly on the shoulder of the
tube fitting body and that the nut is finger-tight.
Scribe the nut at the 6 o'clock position.
While holding the fitting body steady with a back-up
wrench, tighten the nut 1 ¼ turns to the 9 o'clock position.
7

Advertisement

Table of Contents
loading

Table of Contents