SiSG121917E
 Application range is as follows.
 The sensor may not detect moving objects further than 7 m away. (Please see the
 Sensor detection sensitivity changes according to the indoor unit location, the speed of
 The sensor could also mistakenly detect pets, sunlight, fluttering curtains and light reflected
 INTELLIGENT EYE operation will not switch on during POWERFUL operation.
 NIGHT SET mode will not switch on during use of INTELLIGENT EYE operation.

1.12 POWERFUL Operation

Outline
In order to exploit the cooling capacity to full extent, the air conditioner can be operated by
increasing the indoor fan rotating speed and the compressor frequency.
Details
When POWERFUL button is pressed, the fan speed and target temperature are converted to
the following states for 20 minutes.
Ex: POWERFUL operation in cooling
Operation mode
COOL
DRY
FAN
A = 40 ~ 80 rpm (depending on the model)
Note
POWERFUL operation cannot be used together with ECONO, COMFORT AIRFLOW, or
OUTDOOR UNIT QUIET operation.
Part 4 Functions and Control
Vertical angle 90°
(Side view)
application range)
passers-by, temperature range, etc.
off of mirrors as passers-by.
Target temp.
18˚C
POWERFUL
ON
POWERFUL
OFF
Fan
A rpm
H tap
Set tap
Dry rotating speed + A rpm
Wall Mounted and LSP Duct Type Functions
Horizontal
angle 110°
(Top view)
90°
Lower limit of cooling
temperature
20 minutes
Fan speed
H tap + A rpm
H tap + A rpm
55° 55°
(R25176)
Remote controller registers
20 minutes independently.
Ending conditions:
1. Lapse of 20 minutes
2. System operation OFF
3. POWERFUL operation OFF
Target temperature
18°C
Lowered by 2 ~ 2.5°C
(R24808)
54