Outdoor Unit; Mks50/65/80Tvmg, Mkb50/65Tvmg - Daikin MKS-T Series Service Manual

Table of Contents

Advertisement

SiSG121917E

4. Outdoor Unit

4.1

MKS50/65/80TVMG, MKB50/65TVMG

Main PCB (PCB1)
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
13)
14)
15)
16)
17)
V401
U, V, W
Part 3 Printed Circuit Board Connector Wiring Diagram
S
Connector for terminal block (indoor - outdoor transmission)
S20 (white)
Connector for electronic expansion valve coil A port
S21 (red)
Connector for electronic expansion valve coil B port
S22 (blue)
Connector for electronic expansion valve coil C port
S23 (yellow)
Connector for electronic expansion valve coil D port (65/80 class
only)
S40
Connector for overload protector
S70
Connector for outdoor fan motor
S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe
temperature)
S92
Connector for gas pipe thermistor
S93
Connector for liquid pipe thermistor
S201, S202
Connector for service monitor PCB (PCB2)
HL1, HN1
Connector for terminal strip (power supply)
E1, E2
Connector for earth wire
U, V, W
Connector for compressor
FU1, FU2
Fuse (3.15 A, 250 V)
FU3
Fuse (30 A, 250 V)
V2, V3, V401
Varistor
FU1
V2
FU2
S70
E2
E1
V3
HN1
S202
S40
S201

Outdoor Unit

HL1
FU3
S
S23
S22
S21
S20
S92
S93
S90
2P387226-7
2P387226-15
38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents