Daikin MKS-T Series Service Manual page 44

Table of Contents

Advertisement

Outdoor Unit
Service Monitor
1)
PCB (PCB2)
2)
3)
4)
5)
6)
7)
8)
39
S501, S502
Connector for main PCB (PCB1)
LED A
LED for service monitor (green)
LED1, LED2,
LED for service monitor (red)
LED3, LED4,
LED5
SW1
Forced cooling operation ON/OFF switch
Refer to page 183 for details.
SW2
Operation mode switch
Refer to page 183 for details.
SW3
Wiring error check switch
Refer to page 185 for details.
SW4
Priority room setting switch
Refer to page 200 for details.
SW6-1
NIGHT QUIET mode setting switch
Refer to page 201 for details.
LED5 LED4 LED3 LED2 LED1 LED A
SW1
SW3
SW2
 SW6-2 and all the switches of SW5 have no function. Keep them OFF.
SW6-1
SW4
Part 3 Printed Circuit Board Connector Wiring Diagram
SiSG121917E
S501
S502
3P346711-11