Daikin MKS-T Series Service Manual page 26

Table of Contents

Advertisement

Indoor Unit
Model
Rated Capacity
H
M
Airflow Rates
L
SL
Type
Fan
Motor Output
Speed
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor (Rated)
Temperature Control
Dimensions (H × W × D)
Packaged Dimensions (H × W × D)
Weight (Mass)
Gross Weight (Gross Mass)
Sound
Pressure
H / M / L / SL
Level
External Static Pressure
Heat Insulation
Liquid
Piping
Gas
Connection
Drain
Drawing No.
Notes:
1. SL: The Quiet fan level of the airflow rate setting.
21
FDKS50CVMB
5.0 kW Class
12.0 (424)
11.0 (388)
m³/min
(cfm)
10.0 (353)
8.4 (297)
Sirocco Fan
W
130
Steps
5 Steps, Quiet, Auto
Removable, Washable, Mildew Proof
A
0.64
W
140
%
95.1
Microcomputer Control
mm
200 × 900 × 620
mm
266 × 1,106 × 751
kg
27
kg
34
dB(A)
37 / 35 / 33 / 31
Pa
40
Both Liquid and Gas Pipes
mm
φ 6.4
mm
φ 12.7
mm
VP20 (O.D. φ 26 / I.D. φ 20)
C: 3D060040
SiSG121917E
50 Hz, 230 V
FDKS60CVMB
6.0 kW Class
16.0 (565)
14.8 (523)
13.5 (477)
11.2 (395)
Sirocco Fan
130
5 Steps, Quiet, Auto
Removable, Washable, Mildew Proof
0.74
160
94.0
Microcomputer Control
200 × 1,100 × 620
266 × 1,306 × 751
30
37
38 / 36 / 34 / 32
40
Both Liquid and Gas Pipes
φ 6.4
φ 12.7
VP20 (O.D. φ 26 / I.D. φ 20)
C: 3D065479
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Part 2 Specifications

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents