H3: Analog Inputs - YASKAWA HV600 Technical Reference

Ac drive bypass for hvac fan and pump applications
Hide thumbs Also See for HV600:
Table of Contents

Advertisement

C1: AUTO Mode
Setting Value
Function
C1
AUTO Mode
C2: OFF Mode
Setting Value
Function
C2
OFF Mode
C3: Main Feedback Lost
Setting Value
Function
C3
Main Feedback Lost
C4: Backup Feedback Lost
Setting Value
Function
C4
Backup Feedback Lost
100 to 1C4: Inverse Outputs of 0 to C4
Setting Value
Function
100 to 1C4
Inverse Outputs of 0 to C4
For example, set H2-xx = 10E for the inverse output of E [Fault].

H3: Analog Inputs

WARNING! Sudden Movement Hazard. Do test runs and examine the drive to make sure that the command references are correct.
If you set the command reference incorrectly, it can cause damage to the drive or serious injury or death.
Drives have two analog input terminals, terminals A1 and A2. H3 parameters select the functions set to these analog
input terminals and adjust signal levels.
Table 5.43
shows the functions that you can set to analog input terminals. Use H3-02 and H3-10 [MFAI Function
Selection] to set functions.
Setting
Function
Value
0
Frequency Reference
1
Frequency Gain
2
Auxiliary Frequency Reference 1
3
Auxiliary Frequency Reference 2
4
Output Voltage Bias
5
Accel/Decel Time Gain
6
DC Injection Braking Current
7
Torque Detection Level
8
Stall Prevent Level During Run
9
Output Frequency Lower Limit
B
PID Feedback
C
PID Setpoint
D
Frequency Bias
YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
The terminal activates when the drive is in AUTO Mode operation.
The terminal activates when the drive is in OFF Mode operation.
The terminal activates when the drive loses the main PID feedback.
The terminal activates when the drive loses the backup PID feedback.
Causes inverse output of the function for the selected MFDO. Uses the last two digits of 1xx to select which function to inversely
output.
Table 5.43 MFAI Setting Values
Ref.
298
298
299
299
299
299
300
300
300
301
301
301
301
Description
Description
Description
Description
Description
Setting
Function
Value
E
Motor Temperature (PTC Input)
F
Not Used
16
Differential PID Feedback
1F
Not Used
24
PID Feedback Backup
25
PI2 Control Setpoint
26
PI2 Control Feedback
27
PI Auxiliary Control Feedback
2B
Emergency Override PID Feedback
2C
Emergency Override PID Setpoint
2D
Differential Level Source
2E
Hand Frequency Ref or Setpoint
5.7 H: Terminal Functions