When you set the "ST-LR" source to "Digital", you cannot record the stereo
<Note>:
buss signals to the ST tracks.
6)
Press the [EXIT] key repeatedly until you exit the MENU mode.
<Note>:
The display examples below show when channel pairs are set to "DIGITAL"
on the record source select screen. The digital signal format (AES/EBU or S/P DIF) is
automatically detected. If a valid digital signal is not available, the record source
automatically switches to the analog signals.

Digital output signal format selection [Digital out]

The "Digital out" menu item selects the format (AES/EBU or S/P DIF) of the digital signal which
is output from the [DIGITAL I/O] connector.
1)
While the unit is stopped, press the [SHIFT] key to light the SHIFT indicator, followed by the
[ENTER/YES] key.
2)
While "SYS SETUP" is highlighted, press the [ENTER/YES] key.
The display now shows the SYS SETUP menu screen.
3)
Use the [MENU] dial to select the "Digital out" menu item and press the [ENTER/YES] key.
The current setting starts flashing and you can now select the desired option.
You can select from among "AES/EBU" and "S/P DIF" (the default is "AES/EBU").
AES/EBU
S/P DIF
4)
Use the [MENU] dial to select the desired option and press the [ENTER/YES] key to confirm
your setting.
5)
Press the [EXIT] key repeatedly until you exit the MENU mode.
When CH1-2 and CH3-4
<Default>
are set to "DIGITAL"
IEC 60958 Part3 (AES/EBU) format digital signal is output.
IEC 60958 Part2 (S/P DIF) format digital signal is output.
Chapter 8: MENU mode/SYS SETUP menu
Options
Location Recorder Model PD606
When all channels are
set to "DIGITAL"
Flashing