Copyright information
]
© COPYRIGHT 2006, EXTRON ELECTRONICS IPL T Sx, Vx.xx
Mon, 17 Feb 2006 11:27:33
The copyright message is displayed upon connecting to the IP Link
TCP/IP or Telnet. Sx is the model and Vx.xx is the firmware version number. The
current date and time is displayed. This is followed by a password prompt.

Password information

The "
followed by a carriage return. The prompt is repeated if the correct password is not
entered.
If the correct password is entered, the unit responds with "
]
" or "
4-4
IPL T S Series • Communication and Control
= Daylight saving time (DST) is a 1-hour offset (for the USA only) that begins on the first Sunday
of April at 2 am and ends on the last Sunday of October. For example, time in California is
GMT -8:00 from April to October and GMT -7:00 from November to March. DST should be
turned off in Hawaii, American Samoa, Guam, Puerto Rico, the Virgin Islands, the eastern
time zone portion of the state of Indiana, and the state of Arizona (excluding the Navajo
Nation). 0 = off/ignore; 1 = on
= Event number: range = 0–99 (max.)
= Event buffer: 0 = receive; 1 = user (absolute); 2 = user (relative); 3 = NVRAM
= Memory location: range = 0–max. BufferSize
= Event data size: b = bit; B = byte (8 bit); S = short (16 bit); L = long (32 bit)
N
This parameter is case sensitive.
= Event data to write
= Reading password: responds as empty if no password is set, and 4 asterisks (****) if password
exists.
= Number of bytes to read: range = 1–127 (max.)
= E-mail event number: range = 1–48 (max.)
= E-mail recipient address
= Name of e-mail file to be sent.
E-mail files must have the file extension .eml.
N
= Default name: a combination of the model-name and the last 3 pairs of the MAC address (e.g.,
IPL-T-S2-00-02-3D)
= Redirect: 0 = no redirect; 1–n = redirect serial port from the specified port to allow for a
transparent pass-through mode
= Connection's security level: 0 = not logged in; 1 = user; 2 = administrator
= Timeout for data pass-through mode, after which event data can be inserted into the transmit
buffer.
= ASCII digit(s) representing numeric value of data element read from event buffer. (Leading
zeros are suppressed.)
= Time in seconds to keep sending the broadcast message
(0–255, default = 10)
= The number of seconds before timeout on IP connections: (min. = 1; max. = 65000;
default= 30 = 300 seconds). If no data is received during the timeout period, the Ethernet
connection is closed. Each step = 10 seconds. When connected via RS-232, only the global
timeout commands apply. Current returns E13. The response is returned with leading
zeros.
X6(
N
is applicable to Ethernet only.
= Number (as optional parameter) inserted into an e-mail message if the .eml file has an
embedded ESC CR command with no parameters.
= Hardware (MAC) address: the four most significant hex nibbles converted into a single 16-bit
decimal number.
= Hardware (MAC) address: the eight least significant hex nibbles converted into single 32-bit
decimal number.
N
This could be as large as 10 digits.
]
]
Password:" prompt requires a password (administrator level or user level)
]
]
Login User
", depending on the password entered. If the passwords
]
product via
®
]
Login Administrator