SECTION 1 – GENERAL INFORMATION AND SAFETY
Heat Radiation
Some of the visible parts like discharge pipe and driver heat
sink may work under high temperatures, thus radiate high heat
flux. Special attention must be paid while getting close to the
unit. Touching is prohibited during normal operation.
Rotating Parts
Fan guards must be fitted at all times and not removed unless
the power supply has been isolated.
Sharp Edges
The fins on the air-cooled condenser coils have sharp metal
edges. Reasonable care should be taken when working in
contact with the coils to avoid the risk of minor abrasions and
lacerations. The use of gloves is recommended.
Frame rails, panels, and other components may also have
sharp edges. Reasonable care should be taken when working in
contact with any components to avoid risk of minor abrasions
and lacerations.
Refrigerants and Oils
Refrigerants and oils used in the unit are generally non-toxic,
non-flammable and non-corrosive, and pose no special safety
hazards. They are pre-charged before delivery to customer and
normally dispense with the need of additional charging, unless
the machine is not working properly.
Use of gloves and safety glasses is, however, recomm-ended
when working on the unit. The buildup of refrigerant vapor,
from a leak for example, does pose a risk of asphyxiation in
confined or enclosed spaces and attention should be given to
good ventilation.
10
Cooke Industries - Phone: +64 9 579 2185
High Temperature and Pressure Cleaning
High temperature and pressure cleaning methods (e.g. steam
cleaning) should not be used on any part of the pressure system
as this may cause operation of the pressure relief device(s).
Detergents and solvents, which may cause corrosion, should
also be avoided.
Emergency Shutdown
In case of emergency, the HMI panel or the control panel is
fitted with a Unit Switch to stop the unit in an emergency. When
operated, it removes the low voltage 230 VAC electrical supply
of the control panel, thus shutting down the unit.
Safety Labels
The following labels are fixed to each unit to give instruction,
or to indicate potential hazards which may exist.
Black symbol on yellow background
Warning: This machine may start automatically
without prior warning
Black symbol on yellow background
Warning: Hot surface
Black symbol on yellow background
Warning: Safety relief valve may discharge gas
or liquid without prior warning
Black symbol on yellow background
Warning: Isolate all electrical sources of supply
before opening or removing the cover, as lethal
voltages may exist
Black symbol on yellow background
General attention symbol
Email: sales@cookeindustries.co.nz
FORM NO.:6U6K-B01E-NB-EN
JOHNSON CONTROLS
Web: www.cookeindustries.co.nz