York YHJD18 THRU 60 Technical Manual

York YHJD18 THRU 60 Technical Manual

Split-system heat pumps 13 seer – r-410a
Hide thumbs Also See for YHJD18 THRU 60:

Advertisement

TECHNICAL GUIDE
SPLIT-SYSTEM
HEAT PUMPS
13 SEER – R-410A
MODELS:
YHJD18 THRU 60
(1.5 THRU 5 NOMINAL TONS - 1 PHASE)
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The heat pump condensing unit is the outdoor part of a versatile
system of heating and air conditioning. It is designed to be cus-
tom-matched with one of UPG's complete line of evaporator
sections, with each serving a specific function. Matching Air
Handlers are available for upflow, downflow, or horizontal appli-
cations to provide a complete system. Electric Heaters are
available, if required. Add-on coils are available for use with
upflow, downflow, or horizontal furnaces and air handlers.
WARRANTY
Single Phase Units:
5-year limited parts warranty.
10-year limited compressor warranty.
FEATURES
• QUALITY CONDENSER COILS - The coil is constructed of
copper tubing and enhanced aluminum fins for increased
efficiency and corrosion protection.
• PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure, temperature, and
externally by a factory installed high pressure switch. This is
accomplished by the simultaneous operation of high pres-
sure relief valve and a temperature sensor which protects the
compressor if undesirable operating conditions occur. A liq-
uid line filter-drier further protects the compressor.
• DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs are
reduced by easy power and control wiring connections.
Available in sweat connect models only. The unit contains
enough refrigerant for matching indoor coils and 15 feet of
interconnecting piping. The small base dimension means
less space is required on the ground or roof.
• TOP DISCHARGE - The warm air from the top mounted fan
is blown up away from the structure and any landscaping.
This allows compact location on multi-unit applications.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise away from the living area.
The rigid top panel effectively isolates any motor sound. Iso-
lator mounted compressor and the rippled fins of the con-
denser coil muffle the normal fan motor and compressor
operating sounds.
• LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
ISO 9001
Certified Quality
• EASY SERVICE ACCESS - Fully exposed refrigerant con-
Management System
nections, and a single panel covering the electrical controls
make for easy servicing of the unit.
• SECURED SERVICE VALVES - Secured re-usable service
valves are provided on both the liquid and vapor sweat con-
nections for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
• Agency Listed - U.L. and C.U.L. listed - approved for out-
door application. The unit is certified in accordance with the
Unitary Small Equipment certification program, which is
based on ARI Standard 210/240.
397855-YTG-F-0409

Advertisement

Table of Contents
loading

Summary of Contents for York YHJD18 THRU 60

  • Page 1 The unit is certified in accordance with the are subject to change without notice. Unitary Small Equipment certification program, which is Visit us on the web at www.york.com based on ARI Standard 210/240. Additional rating information can be found at www.ahridirectory.org...
  • Page 2: Physical And Electrical Data

    397855-YTG-F-0409 Physical and Electrical Data YHJD18 YHJD24 YHJD30 YHJD36 YHJD42 YHJD48 YHJD60 MODEL S41S1 S41S1 S41S1 S41S1 S41S1 S41S1 S41S2 Unit Supply Voltage 208-230V, 1 60Hz 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 12.0 15.4 19.6 28.6 30.9 37.4 Max.
  • Page 3: Table Of Contents

    System Charge for Various Matched Systems YHJD18 YHJD24 YHJD30 YHJD36 YHJD42 YHJD48 YHJD60 Outdoor Unit S41S1 S41S1 S41S1 S41S1 S41S1 S41S1 S41S2 1TVM04E1 1TVM04G1 1TVM04G1 1TVM04H1 1TVM04H1 1TVM04J1 1TVM04K1 Required Orifice or TXV Factory Charge, lbs-oz 6 - 5 8 - 7 9 - 12 9 - 15 9 - 12...
  • Page 4 397855-YTG-F-0409 COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL SEER TOTAL SENS. 13 SEER HP WITH MA MA08B FC/MC/PC18B 17.0 12.6 13.00 11.00 YHJD18S41S1 MA08B FC/MC/PC24B 17.0 12.9 13.50 11.00 YHJD24S41S1 MA08B FC/MC/PC35B...
  • Page 5 COOLING CAPACITY - With Air Handler Coils (Continued) AIR HANDLER COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL SEER TOTAL SENS. AHP36 – 1000 29.0 23.2 13.00 11.00 YHJD30S41S1 AHX36 – 1005 29.6 24.6 14.30 12.00 F6FP036 – 29.0 23.4 14.00 12.00...
  • Page 6 397855-YTG-F-0409 COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils FURNACE** COOLING COIL NET MBH UNIT MODEL CFM RANGE RATED MODEL SEER (Min.-max.) TOTAL SENS. 450 - 750 14,17 FC/MC/PC18 17.0 12.6 13.00 11.00 450 - 750 14,17 FC/MC/PC24 17.0 12.9 13.50...
  • Page 7 COOLING CAPACITY - With High Efficiency Motor Furnaces COOLING UNIT FURNACE COIL Net MBH RATED MODEL MODEL MODEL SEER TOTAL SENS. 13 SEER HP WITH VARIABLE SPEED FURNACES Y*(8,L)C*A12 FC/MC/PC18A 17.6 12.3 14.50 12.30 Y*(8,L)C*B12 FC/MC/PC18B 17.4 11.9 14.40 12.20 Y*9C*B12 FC/MC/PC18B 17.6...
  • Page 8 397855-YTG-F-0409 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) COOLING UNIT FURNACE COIL Net MBH RATED MODEL MODEL MODEL SEER TOTAL SENS. 13 SEER HP WITH VARIABLE SPEED FURNACES Y*9C*C16 FC/MC/PC43C 1030 29.6 22.2 14.00 12.60 Y*9C*C20 FC/MC/PC43C 29.6 22.4 14.40 12.80...
  • Page 9 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) COOLING UNIT FURNACE COIL Net MBH RATED MODEL MODEL MODEL SEER TOTAL SENS. 13 SEER HP WITH VARIABLE SPEED FURNACES T*(8,L)X*C16 FC/MC/PC48C 1360 41.5 31.4 13.80 11.75 T*9X*C16 FC/MC/PC48C 1425 41.5 31.8 13.60 11.50...
  • Page 10 397855-YTG-F-0409 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) COOLING UNIT FURNACE COIL Net MBH RATED MODEL MODEL MODEL SEER TOTAL SENS. 13 SEER HP WITH VARIABLE SPEED FURNACES T*(8,L)X*C16 FC/PC60C 1605 46.5 34.6 13.50 11.50 T*9X*C16 FC/PC60C 1575 46.5 34.6 13.30...
  • Page 11 HEATING PERFORMANCE - With Air Handler ARI HEATING UNIT COIL 47F 17F HSPF MODEL* HANDLER MODEL 13 SEER HP WITH MA MA08B FC/MC18B 17.0 3.32 1.50 12.7 3.00 1.24 7.70 YHJD18S41S1 MA08B FC/MC24B 17.0 3.44 1.45 10.4 2.60 1.17 7.70 YHJD24S41S1 MA08B FC/MC/PC35B...
  • Page 12: Yhjd18S41S1

    397855-YTG-F-0409 HEATING PERFORMANCE - With Air Handler (Continued) ARI HEATING UNIT COIL 47F 17F HSPF MODEL* HANDLER MODEL 13 SEER HP WITH AHP / SHP / AHX / F*FP AHP18 – 17.0 3.38 1.47 2.16 1.11 7.70 YHJD18S41S1 F4FP24 – 17.0 3.34 1.49...
  • Page 13: Yhjd24S41S1

    HEATING PERFORMANCE - Upflow, Downflow, and Horizontal Furnaces and Coils ARI HEATING UNIT COIL 47F 17F HSPF MODEL* MODEL FC/MC/PC/UC18 17.0 3.32 1.50 12.7 3.00 1.24 7.70 FC/MC/PC/UC24 17.0 3.44 1.45 10.4 2.60 1.17 7.70 YHJD18S41S1 HC18 17.0 3.32 1.50 12.7 3.00 1.24...
  • Page 14: Fc/Mc/Pc32A

    397855-YTG-F-0409 HEATING CAPACITY - With High Efficiency Motor Furnaces ARI HEATING FURNACE COIL MODEL 47F 17F HSPF MODEL MODEL 13 SEER HP WITH VARIABLE SPEED FURNACES Y*(8,L)C*A12 FC/MC/PC18A 16.7 3.58 1.37 2.28 0.99 8.00 Y*(8,L)C*B12 FC/MC/PC18B 16.6 3.56 1.37 2.30 0.98 7.90 Y*9C*B12...
  • Page 15 HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued) ARI HEATING FURNACE COIL MODEL 47F 17F HSPF MODEL MODEL Y*9C*B12 FC/MC/PC43B 28.0 3.50 2.34 16.3 2.48 1.93 7.90 Y*(8,L)C*C16 FC/MC/PC43C 27.6 3.62 2.23 16.0 2.56 1.83 8.00 Y*(8,L)C*C20 FC/MC/PC43C 27.6 3.62 2.23 16.0...
  • Page 16 397855-YTG-F-0409 HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued) ARI HEATING FURNACE COIL MODEL 47F 17F HSPF MODEL MODEL T*(8,L)X*C16 FC/MC/PC48C 41.0 3.82 3.15 27.6 2.66 3.04 8.20 T*9X*C16 FC/MC/PC48C 41.5 3.80 3.20 27.8 2.64 3.09 8.10 T*(8,L)X*C20 FC/MC/PC48C 41.5 3.88 3.13...
  • Page 17 HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued) ARI HEATING FURNACE COIL MODEL 47F 17F HSPF MODEL MODEL T*(8,L)X*C16 FC/PC60C 47.0 3.46 3.98 32.8 2.28 4.22 8.00 T*9X*C16 FC/PC60C 47.0 3.46 3.98 32.8 2.28 4.22 8.00 T*(8,L)X*C20 FC/MC/PC60D 47.0 3.48 3.96 32.8...
  • Page 18 397855-YTG-F-0409 ACCESSORIES Room Thermostats - A wide selection of matching thermostats is available to provide features required for any installation. Refer to Price Manual for specific model numbers. 2H/1C, manual changeover electronic non-programmable ther- Start Assist Kit (2SA067*) - May be required on 42, 48, 60 mostat.
  • Page 19: Typical Installation

    TYPICAL INSTALLATION MINIMUM 24” SERVICE ACCESS CLEARANCE THERMOSTAT 48” OVERHEAD ON ONE SIDE CLEARANCE WEATHERPROOF DISCONNECT SWITCH NEC CLASS 1 WIRING 10” CLEARANCE TO FURNACE OR AROUND PERIMETER AIR HANDLER TERMINAL BLOCK NEC CLASS 2 WIRING TO INDOOR COIL NOTE: ALL OUTDOOR WIRING CONTROL MUST BE WEATHERPROOF.
  • Page 20 397855-YTG-F-0409 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. YHJD18S41S1 INDOOR COIL MODEL NO. AHP18 IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 17.6 20.2 20.2 22.5 24.9 20.4 21.5 21.8 24.2 26.7 23.2 22.7 23.4 25.9 28.4 S.C.
  • Page 21: Ahx30

    COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. YHJD24S41S1 INDOOR COIL MODEL NO. AHP30 IDCFM 1000 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 22.9 26.4 25.6 29.2 31.5 25.8 28.0 27.2 30.7 33.2 28.8 29.6 28.8 32.2 35.0 S.C.
  • Page 22 397855-YTG-F-0409 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. YHJD30S41S1 INDOOR COIL MODEL NO. AHP36 IDCFM 1000 1200 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 28.5 30.9 31.1 34.0 37.0 30.8 32.4 32.4 35.6 38.7 33.1 33.9 33.7 37.2 40.5...
  • Page 23 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. YHJD36S41S1 INDOOR COIL MODEL NO. AHP36 IDCFM 1000 1200 1400 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 37.0 40.3 39.8 43.7 47.3 39.3 41.5 41.2 45.3 48.9 41.6 42.6 42.7 46.8 50.5...
  • Page 24: Ahx42

    397855-YTG-F-0409 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. YHJD42S41S1 INDOOR COIL MODEL NO. FC/MC/PC48 IDCFM 1200 1400 1600 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 39.7 42.2 42.3 46.6 50.3 41.4 43.0 43.0 47.1 51.6 43.2 43.9 43.7 47.7...
  • Page 25 Furnaces Coils T.C. S.C. Furnaces Coils T.C. S.C. Y*(8,L)C*C16 HC42 1.01 1.02 0.96 T*(8,L)X*C16 FC/MC/PC48C 1.00 1.05 0.95 Y*(8,L)C*C20 HC42 1.01 1.02 0.96 T*9X*C16 FC/MC/PC48C 1.01 1.07 0.97 Y*9C*C16 HC42 1.01 1.01 0.97 T*(8,L)X*C20 FC/MC/PC48C 1.02 1.09 0.96 Y*9C*C20 HC42 1.01 1.01 0.97...
  • Page 26 397855-YTG-F-0409 COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. YHJD48S41S1 INDOOR COIL MODEL NO. AHP/SHP48 IDCFM 1400 1600 1800 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 46.3 49.0 49.0 53.3 57.3 48.3 49.9 49.7 54.0 58.4 50.2 50.8 50.4 54.8...
  • Page 27: Ahx60

    COOLING PERFORMANCE DATA CONDENSING UNIT MODEL NO. YHJD60S41S1 INDOOR COIL MODEL NO. FC/MC62 IDCFM 1600 1800 2000 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 54.0 57.1 56.9 62.3 67.6 56.0 57.9 57.8 63.4 69.1 58.0 58.7 58.7 64.4 70.5...
  • Page 28: Av*24

    397855-YTG-F-0409 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO YHJD18S41S1 EVAPORATOR COIL MODEL NO AHP18 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 19.7 21.0 22.3 18.3 19.6 20.9 16.8 18.1 19.5 16.4 17.6...
  • Page 29: F6Fp030

    HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO YHJD24S41S1 EVAPORATOR COIL MODEL NO AHP24 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1000 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 28.4 30.1 31.8 26.7 28.4 30.1 25.1 26.8 28.5 23.4 24.5...
  • Page 30 397855-YTG-F-0409 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO YHJD30S41S1 EVAPORATOR COIL MODEL NO AHP36 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1000 1200 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 33.0 35.7 38.5 31.4 34.1 36.9 29.8 32.5 35.2...
  • Page 31: F6Fp048

    HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO YHJD36S41S1 EVAPORATOR COIL MODEL NO AHP36 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1000 1200 1400 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 44.9 46.3 47.8 42.7 44.3 45.8 40.6 42.2 43.9...
  • Page 32: Ytg-F

    397855-YTG-F-0409 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO YHJD42S41S1 EVAPORATOR COIL MODEL NO FC/MC/PC/UC48 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1200 1400 1600 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 48.7 48.7 48.7 47.8 48.6 49.5 46.8 48.6...
  • Page 33: Fc/Mc/Pc48D

    Furnaces Coils Furnaces Coils Y*(8,L)C*C16 HC42 0.99 1.03 0.96 T*(8,L)X*C16 FC/MC/PC48C 0.98 1.05 0.94 Y*(8,L)C*C20 HC42 0.99 1.03 0.96 T*9X*C16 FC/MC/PC48C 0.99 1.04 0.95 Y*9C*C16 HC42 0.99 1.02 0.98 T*(8,L)X*C20 FC/MC/PC48C 0.98 1.06 0.93 Y*9C*C20 HC42 0.99 1.02 0.97 T*9X*C20 FC/MC/PC48C 0.98 1.05...
  • Page 34: Fc/Mc/Pc48C

    397855-YTG-F-0409 HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO YHJD48S41S1 EVAPORATOR COIL MODEL NO AHP/SHP48 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1400 1600 1800 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 60.1 61.4 62.7 59.0 59.2 61.1 57.9 57.0...
  • Page 35: Fc/Mc/Pc60D

    HEATING PERFORMANCE DATA CONDENSING UNIT MODEL NO YHJD60S41S1 EVAPORATOR COIL MODEL NO FC/MC62 ID CFM AIR TEMP. AIR TEMP. ENTERING ENTERING 1600 1800 2000 OUTDOOR UNIT INDOOR COIL MBTUH C.O.P. MBTUH C.O.P. MBTUH C.O.P. 65.7 66.7 67.6 64.7 65.4 66.1 63.8 64.1 64.5...
  • Page 36: Ytg-F

    Subject to change without notice. Printed in U.S.A. 397855-YTG-F-0409 Copyright © 2009 by Johnson Controls, Inc. All rights reserved. Supersedes: 397855-YTG-E-0309 Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069...

Table of Contents