York YMGE36BNO-MS-X User Manual

Rooftop package, 50hz r-410a

Advertisement

User's Manual
50HZ R-410a Heat Pump
Rooftop Package
New Released
R-410
YMGE36BNO--MS-X
YMGE48BNO--MS-X
YMGE60BNO--MS-X
Issue Date
Issue Date
Jan 31st, 2017
Form: MMGEBNO--MS-X-170131

Advertisement

Table of Contents
loading

Summary of Contents for York YMGE36BNO-MS-X

  • Page 1 Rooftop Package User's Manual New Released Form: MMGEBNO--MS-X-170131 50HZ R-410a Heat Pump R-410 YMGE36BNO--MS-X YMGE48BNO--MS-X YMGE60BNO--MS-X Issue Date Issue Date Jan 31st, 2017...
  • Page 2 Multi Splits High Wall DC Inverter User's Manual New Released Rooftop Package Type R-410 YMGE36BNO--MS-X YMGE48BNO--MS-X YMGE60BNO--MS-X Issue Date Jan 1st, 2017...
  • Page 3 General Description As the name Rooftop signifies, this unit is generally installed on the top of the roof. Also the Single Package signifies that both condenser and evaporator are enclosed in a single body(same as window type). In fact, The unit can be ideal for either rooftop or on-the-ground installation.The unit is provided with excellent performances that can be operated up to 43°C of maximum ambient temperature.
  • Page 4: Table Of Contents

    Table of contents Read this manual carefully before attempting to install, operate, or perform maintenance on this unit. Installation and maintenance should be performed by qualified service technicians only. CONTENT PAGE Reconnect all grounding devices. All parts of this product capable ACCESSORIES-------------------------------------------------------------1 of conducting electrical current are grounded.
  • Page 5: Dimensional Data

    3. DIMENSIONAL DATA Figure 1 I&O manual...
  • Page 6: Installation

    4. INSTALLATION ■ The frame must be located and secured by bolting or welding to the roof. Flashing is required. LOCATIONS AND RECOMMENDATIONS ■ The hole in the roof must be prepared in advance of installing the unit. ■ The unit is designed for outdoor installations only. The unit may be installed directly on wood flooring or on Class A, Class B, ■...
  • Page 7: Electrical Wiring

    4.4 MAXIMUM FOUNDATION GRADIENT 4.6 DUCTWORK Note: Make sure that Condensate Drain side is not higher than the other side. All conditioned air ductwork should be insulated to minimize MAXIMUM FOUNDATION GRADIENT heating and cooling duct losses. Use a minimum of two (2) inches TYPICAL of insulation with a vapor barrier.
  • Page 8 NOTE Knock down the control box access panel, first twist off screws and then up it, the control box access panel is getting out. CAUTION If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
  • Page 9 T O THE WI RE C O NT ROL LE R BLUE BLUE CN48 CN33 MAIN CONTROL BOARD WIRING DIAGRAM CN13 CODE CN32 CN34 CN35 CN36 CN30 PART NAME CN15 BLUE COMP RT3 RT4 COMPRESSOR FAN1 INDOOR FAN FAN2 OUTDOOR FAN BLACK CAP1 INDOOR FAN CAP...
  • Page 10: Operating Conditions

    TO TH E W IR E CO N TR OL LE R BLUE BLUE CN33 CN48 MAIN CONTROL BOARD WIRING DIAGRAM CN13 CODE PART NAME CN32 CN34 CN35 CN36 CN37 CN30 CN15 BLACK COMP COMPRESSOR BLUE RT3 RT4 PURPLE FAN1 INDOOR FAN FAN2 OUTDOOR FAN...
  • Page 11: Physical Data

    7. PHYSICAL DATA Table 7-1 Component Physical Data 36000 48000 58000 Nominal Capacity Btu/h Nominal Tonnage A R I C O O L I N G SEER PERFORMANCE Refrigerant type R-410A R-410A R-410A 1102 1102 Length (mm) 1102 DIMENSIONS Width (mm) Height (mm) Fins per inch CONDENSER...
  • Page 12: Wind Pressure Data

    8. WIND PRESSURE DATA Table 8-1 Duct Application CFM(L/S)(Watts) Model Motor External Static Pressure-Inches W.C.[kPa] Number Speed 0[0] 0.1[.02] 0.2[.05] 0.3[.07] 0.4[.10] 0.5[.12] 0.6[.15] 0.7[.17] CFM(L/S) 1380(651) 1282(605) 1167(551) 1006(475) 889(420) Watts Amps CFM(L/S) Middle 36HP Watts Amps 1464(691) 1378(650) 1274(601) 1070(505) 947(447)
  • Page 13: Performance Data

    9. PERFORMANCE DATA COOLING PERFORMANCE DATA—36HP(380V, 50Hz, 3Ph) Air Flow (CFM) 1370 1500 Ent (DB) (℉) 27.5 30.9 33.9 35.7 28.1 31.5 34.6 36.4 20.8 24.1 27.1 28.9 21.2 24.6 27.7 29.5 2.69 2.71 2.72 2.73 2.72 2.73 2.75 2.76 28.6 32.3 35.9...
  • Page 14 COOLING PERFORMANCE DATA—48HP(380V, 50Hz, 3Ph) Air Flow (CFM) 1650 1750 1950 Ent(DB) (℉) 36.7 41.1 45.1 47.5 37.4 41.9 46.0 48.5 38.1 42.7 46.9 49.5 27.6 32.0 36.1 38.5 28.2 32.7 36.8 39.3 28.8 33.4 37.5 40.1 4.16 4.19 4.21 4.23 4.21 4.23...
  • Page 15 COOLING PERFORMANCE DATA—60HP(380V, 50Hz, 3Ph) Air Flow (CFM ) 1650 1750 1950 Ent (DB ) (℉) 43.4 48.6 53.4 56.3 44.3 49.6 54.5 57.4 45.2 50.6 55.6 58.6 32.7 37.9 42.7 45.6 33.4 38.7 43.6 46.6 34.1 39.5 44.5 47.5 4.92 4.95 4.97...
  • Page 16: Start

    SYSTEM OPERATION 10. START-UP LED DISPLAY ■ ■ PACKAGING AND COMPONENTS ● Is the unit properly located and level with the proper clearance? The control would display any fault code that is currently active using the LED. The control will display the fault code, when the ●...
  • Page 17: Maintenance

    12. MAINTENANCE CAUTION ■ ROUTINE MAINTENANCE BY OWNER Do not dry out the air filter under direct sunshine or with fire. You can do some of the periodic maintenance functions for your 3. Re-install the air filter unit yourself; this includes cleaning the permanent air filters, cleaning the unit cabinet, cleaning the condenser coil, and conducting a general unit inspection on a regular basis.
  • Page 18 MD14IU-021EW 202000172582...
  • Page 19 更改内容,此页不做菲林 1:a版本升b版本更改说明 试产整改,更换说明书中接线铭牌。 2:b版本升c版本更改说明 更换说明书中60K能力标称。 3:c版本升d版本更改说明 更换说明书中变工况表及故障代码表。 4:d版本升e版本更改说明 更换说明书中风量参数表。...
  • Page 20 2016 Johnson Controls, Inc. www.johnsoncontrols.com Doc. No.: MMGEBNO--MS-X-170131...

This manual is also suitable for:

Ymge48bno-ms-xYmge60bno-ms-x

Table of Contents