Commissioning, inspection, maintenance
Steps - commissioning, inspection and maintenance
Commissioning steps
Inspection steps
Maintenance steps
•
•
•
1. Removing the front panel.................................................................................................. 21
•
2. Filling the heating system................................................................................................. 21
•
3. Checking the power supply
•
4. Changing the language (if required)................................................................................. 22
•
•
5. Setting the time and date (if required).............................................................................. 23
•
6. Venting the boiler............................................................................................................... 23
•
7. Venting the heating system............................................................................................... 23
•
8. Filling the trap with water.................................................................................................. 24
•
9. Naming the heating circuits.............................................................................................. 24
•
•
•
10. Function sequence and possible faults........................................................................... 24
•
•
11. Standard values for burner adjustment........................................................................... 26
•
•
12. Adjusting the oil pressure and checking the vacuum.................................................... 27
•
•
13. Adjusting the air volume (static burner pressure).......................................................... 28
•
14. Cleaning the burner........................................................................................................... 29
•
15. Replacing the nozzle and checking or adjusting the ignition electrodes..................... 30
•
•
16. Cleaning the oil pump filter and replacing it if required................................................. 31
•
•
17. Checking the heat exchanger for contamination............................................................ 33
•
•
18. Cleaning the heat exchanger............................................................................................ 33
•
•
19. Checking the condensate drain and cleaning the trap................................................... 34
•
•
20. Checking the neutralising system (accessories)............................................................ 34
•
•
21. Checking the active charcoal filter (accessories)........................................................... 35
•
•
•
22. Checking the diaphragm expansion vessel and system pressure
•
•
•
23. Checking all connections on the heating water side for leaks
•
•
•
24. Checking the burner (record values on page 114 of the report)
•
•
•
25. Checking the flue system for unrestricted flow and tightness
•
•
•
26. Checking the safety valve function
•
•
•
27. Checking the firm seating of electrical connections
•
28. Matching the control unit to the heating system ........................................................... 35
•
29. Adjusting the heating curves (only for weather-compensated control units).............. 39
•
30. Linking the control unit to the LON.................................................................................. 41
•
31. Instructing the system user.............................................................................................. 42
•
32. Scanning and resetting the "Service" display................................................................. 42
20
Page