Samsung AC009BNLDCH Service Manual page 270

Hide thumbs Also See for AC009BNLDCH:
Table of Contents

Advertisement

Troubleshooting
IPM (Over Current) error (Error Code : E464) (Cont.)
Continue
Is service valve fully opened?
Is compressor wire connected properly
to the compressor?
Check the compressor.
1. Are all the resistance values between
phases matched? (U ↔ V, U ↔ W, V ↔ W)
2. Is compressor wiring normal? (disconnection, wrong connection)
3. Is there any abnormal noise from
compressor rotation?
Is there a reading of MegaΩ of resistance
between compressor body and chassis?
Are the position and measuring value of the
temperature sensor normal?
Continue
4-76
Yes
Yes
Yes
Yes
No
No
Check the connection status of compressor.
1. Replace the compressor : If the resistance value
between phases of the compressor is different.
→ Power on.→ Check the normal operation. → End the
service.
No
2. Reassemble wire : If the wire connection of the
compressor is wrong.
→ Power on. → Check the normal operation. → End the
service.
3. Replace the compressor : When loud abnormal noise
generates (metal cutting or grinding noise), or severe
vibration.
No
Replace the compressor.
No
Turn off the power and change the location
of the temperature sensor or replace it.
Open the valve.