Samsung AR07CSDAFWKN Service Manual
Samsung AR07CSDAFWKN Service Manual

Samsung AR07CSDAFWKN Service Manual

Multi air conditioner
Table of Contents

Advertisement

AIR CONDITIONER
MULTI AIR CONDITIONER
INDOOR UNIT
AR07/15CSDAFWKN
AR09/12/18/24CSDABWKN
AR07/09/12/15/18/24CSFCMWKN
AR07/09/12/15/18/24CSKCPWKN
AC009/012/018BNNDCH
AC009/012/018BNLDCH
AJ009/012/015/018BNHDCH
AC009/012BN1DCH
AC009/012/015/018BNJDCH
AC012/018/024BNZDCH
CONTENTS
1. Precautions
2. Product Specifications
3. Disassembly and Reassembly
4. Troubleshooting
5. PCB Diagram
6. Wiring Diagram
7. Reference Sheet
OUTDOOR UNIT
AJ020BXJ2CH
AJ024BXJ3CH
AJ036BXJ4CH
AJ048BXJ5CH
AJ020CXS3CH
AJ024CXS4CH
AJ030CXS4CH
AJ036CXS4CH

Advertisement

Table of Contents
loading

Summary of Contents for Samsung AR07CSDAFWKN

  • Page 1 MULTI AIR CONDITIONER INDOOR UNIT OUTDOOR UNIT AR07/15CSDAFWKN AJ020BXJ2CH AR09/12/18/24CSDABWKN AJ024BXJ3CH AR07/09/12/15/18/24CSFCMWKN AJ036BXJ4CH AR07/09/12/15/18/24CSKCPWKN AJ048BXJ5CH AC009/012/018BNNDCH AJ020CXS3CH AC009/012/018BNLDCH AJ024CXS4CH AJ009/012/015/018BNHDCH AJ030CXS4CH AC009/012BN1DCH AJ036CXS4CH AC009/012/015/018BNJDCH AC012/018/024BNZDCH AIR CONDITIONER CONTENTS 1. Precautions 2. Product Specifications 3. Disassembly and Reassembly 4. Troubleshooting 5. PCB Diagram 6.
  • Page 2 "look and feel" and arrangement of such Content, contained in this manual is owned, controlled or licensed by or to Samsung, and is protected by trade dress, copyright, patent and trademark laws, and various other intellectual property rights and unfair competition laws.
  • Page 3: Table Of Contents

    Contents 1. Precautions······························································································································1-1 1-1 Precautions for the Service ......................1-1 1-2 Precautions for the Static Electricity and PL................. 1-1 1-3 During operation ..........................1-2 1-4 Disposing of the unit ........................1-2 1-5 Precautions for the Pump Down ..................... 1-2 1-6 Others ..............................1-2 2.
  • Page 4 Contents 4-6-5 Compressor startup error, Compressor lock error, Compressor rotation error ....4-48 4-6-6 IPM Over current error ......................4-49 4-6-7 Checking Temperature sensor ....................4-50 4-7 PCB Inspection ..........................4-52 4-7-1 Cautions for Part Replacement ....................4-52 4-7-2 Procedure ............................. 4-52 5.
  • Page 5: Precautions

    >3mm. • Do not extend an electric cord to the air conditioner. No Tapping and No Extension Cords • The air conditioner must be plugged in after you complete the installation. Samsung Electronics...
  • Page 6: During Operation

    • Current is measured according to ISO standard for energy efficiency. • For servicing the units containing flammable refrigerants, safety checks are required to minimise the risk of ignition. • Servicing shall be performed following the controlled procedure to minimize the risk of flammable refrigerant or gases. Samsung Electronics...
  • Page 7: Product Specifications

    ■ Universal Connection Multi Inverter(Free Joint Multi) Series delivers comfort to 2~5 rooms with a Single Outdoor Unit. Free Joint Multi added Universal indoor units, which can be universally connected to other Samsung outdoor units, to all lineup. ■ Various Indoor units & combinations ·...
  • Page 8 When you want to operate all indoor units with the cooling mode or heating mode. ■ Wi-Fi Fuction (SmartThings app) SmartThings app is the easy way to turn your home into a smart home. Control the FJM with only one application. This feature is optional to the several models. Samsung Electronics...
  • Page 9: Product Specifications

    Product Specifications 2-2 Product Specifications 2-2-1 Indoor Unit Type Wall-mounted Wind-Free QF2 GEO Model AR07CSDAFWKN AR09CSDABWKN AR12CSDABWKN AR15CSDAFWKN Cooling 2.05 2.64 3.52 4.40 Heating 2.20 3.22 3.52 5.28 Capacity Cooling 7,000 9,000 12,000 15,000 Performance Btu/h Heating 7,500 11,000 12,000...
  • Page 10 Cross flow fan Cross flow fan Cross flow fan Type BLDC BLDC BLDC Part Fan Motor Code DB31-00636A DB31-00636A DB31-00636A Row, Heat Exchanger 2Rx16S 2Rx16S 2Rx16S Step Refrigerant Control Device EEV NOT INCLUDED EEV NOT INCLUDED EEV NOT INCLUDED Samsung Electronics...
  • Page 11 Cross flow fan Cross flow fan Cross flow fan Type BLDC BLDC BLDC Part Fan Motor Code DB31-00636A DB31-00636A DB31-00636A Row, Heat Exchanger 2Rx16S 2Rx16S 2Rx16S Step Refrigerant Control Device EEV NOT INCLUDED EEV NOT INCLUDED EEV NOT INCLUDED Samsung Electronics...
  • Page 12 9.52 Type Turbo Fan Turbo Fan Turbo Fan Type BLDC BLDC BLDC Part Fan Motor Code DB31-00578C DB31-00578C DB31-00578C Row, Heat Exchanger 2Rx8S 2Rx8S 2Rx8S Step Refrigerant Control Device EEV NOT INCLUDED EEV NOT INCLUDED EEV NOT INCLUDED Samsung Electronics...
  • Page 13 Cross Flow FAN Type BLDC BLDC BLDC BLDC Part Fan Motor Code DB31-00639B DB31-00639B DB31-00639B DB31-00639B Row, Heat Exchanger 3Rx16S 3Rx16S 3Rx16S 3Rx16S Step Refrigerant Control Device EEV NOT INCLUDED EEV NOT INCLUDED EEV NOT INCLUDED EEV NOT INCLUDED Samsung Electronics...
  • Page 14 15.88 Type Sirroco FAN Sirroco FAN Sirroco FAN Type BLDC BLDC BLDC Part Fan Motor Code DB81-05891A DB81-04294H DB81-04294J Row, Heat Exchanger 2Rx24S 3Rx24S 3Rx24S Step Refrigerant Control Device EEV NOT INCLUDED EEV NOT INCLUDED EEV NOT INCLUDED Samsung Electronics...
  • Page 15: Outdoor Unit

    10.01 10.01 Part Type BLDC BLDC BLDC BLDC Fan Motor Code DB31-00579A DB31-00579A DB31-00579A DB31-00579A Row, Heat Exchanger 2R*36S 2R*36S 2R*46S 2R*56S Step Refrigerant Control Device Type R-410A R-410A R-410A R-410A Refrigerant Factory Charging 2200 2650 3100 3800 Samsung Electronics...
  • Page 16 10.01 Part Type BLDC BLDC BLDC BLDC Fan Motor Code DB31-00579A DB31-00579A DB31-00579A DB31-00579A Row, Heat Exchanger 2R*56S 2R*56S 2R*56S 2R*56S Step Refrigerant Control Device Type R-410A R-410A R-410A R-410A Refrigerant Factory Charging 3600 3600 3600 3600 2-10 Samsung Electronics...
  • Page 17: The Comparative Specifications Of Product

    Specifications Noise Type Design Model Name [dB(A)] Net Size Net Weight [W*H*D,mm] [kg] Sound Pressure AJ020BXJ2CH 53.0 880x798x310 AJ024BXJ3CH 57.0 AJ036BXJ4CH 940x998x330 76.5 Normal Outdoor AJ048BXJ5CH 940x1210x330 87.5 AJ020CXS3CH 86.5 Max Heat 940x1210x330 AJ024CXS4CH AJ030CXS4CH 87.5 AJ036CXS4CH Samsung Electronics 2-11...
  • Page 18 AR15/18/24CSFCMWKN 41/41/45 1055*299*215 11.5/13.3 AR15/18/24CSKCPWKN 41/41/45 AC009/012BN1DCH 970*135*410 32/35 Cassette AC009/012/018BNNDCH 575*250*575 11.6 31/34/39 Indoor AC009/12BNLDCH 900*199*440 18.9 33/34 AC018BNLDCH 1100*199*440 22.4 Duct 850*250*700 26.7 30/31/33/34 AJ009/012/015/018BNHDCH Console AC009/012/015/018BNJDCH 720*620*199 15.7/15.7/15.9/15.9 35/38/42/43 MPAH AC012/018/024BNZDCH 445*1092*533 43.5/44.5/44.5 38/40/43 2-12 Samsung Electronics...
  • Page 19: Combination Table (Outdoor-Indoor)

    Product Specifications 2-4 Combination Table (Outdoor-Indoor) Design Model Name Model AJ020BXJ2CH AJ024BXJ3CH AJ036BXJ4CH AJ048BXJ5CH AJ020CXS3CH AJ024CXS4CH AJ030CXS4CH AJ036CXS4CH Capacity Model [kBtu/h] AR07CSDAFWKN 7/9/12 ● ● ● ● ● ● ● ● AR09/12CSDABWKN AR15CSDAFWKN ● ● ● ● ● ● ●...
  • Page 20 Not Allowed Allowed Allowed ≤ 1.0 JXH30S4C (AJ030CXS4CH/AA) Not Allowed Not Allowed Allowed Allowed ≤ 1.0 JXH36S4C (AJ036CXS4CH/AA) Not Allowed Not Allowed Allowed Allowed ≤ 1.0 *Mixed installation means mixing AJ***BNHDCH/AA and AC***BNZDCH/AA units on the same system. 2-14 Samsung Electronics...
  • Page 21: Accessory And Option Specifications

    Item Description Code No. Remark AC009BN1DCH AC012BN1DCH DB69-01947A,B PAD INSTALL DB69-03017C,D SEAL-DRAIN ASSY DB62-05810A HOSE DRAIN-JOINT DB94-01258C GROMMET-HANGER DB63-00237A MANUAL USERS DB68-11305A Indoor Unit MANUAL INSTALL DB68-11272A INSULATION-BASE DB72-00401C CABLE TIE DB65-10088C CARD WARRANTY 6801-002246 BRACKET-BUSHING DB61-04340A Samsung Electronics 2-15...
  • Page 22 ■ AC***BNNDCH Item Description Code No. Q’ty Remark ASSY DRAIN-HOSE DB94-03287A CABLE TIE DB65-10088C SEAL-DRAIN ASSY DB62-11028A Essential Offer SEAL-DRAIN ASSY DB62-11028H (Indoor Unit) SEAL-DRAIN ASSY DB62-11028J MANUAL USERS DB68-11208A MANUAL INSTALL DB68-11209A CARD WARRANTY 6801-002246 BRACKET-CONDUIT DB61-05788A 2-16 Samsung Electronics...
  • Page 23 MANUAL USERS AJ***BNHDCH : DB68-11295A AC***BNLDCH : DB68-11207A MANUAL INSTALL AJ***BNHDCH : DB68-11296A INSULATION-COVER BAND DB62-04318S INSULATION-HOSE DB62-11028M INSULATION-HOSE D DB62-11028E Indoor Unit ASSY DRAIN HOSE DB62-11028F INSULATION-TUBE OUT DB94-06964B GROMMET-HANGER DB63-00237A CARD WARRANTY 6801-002246 CABLE TIE 6501-001110 Samsung Electronics 2-17...
  • Page 24 Description Code No. Q’ty Remark ASSY WIRELESS REMOCON DB96-24901P BATTERY-MN 4301-000121 MANUAL USERS DB68-11212A Essential Offer (Indoor Unit) MANUAL INSTALL DB68-11213A HOLDER-REMOCON DB61-06087A SCREW-TAPPING(M4*L12) 6002-000213 CARD WARRNATY 6801-002246 SEAL-INSTALL OUTLET B62-05580V SEAL-PIPE SVC DB62-05691C CABLE TIE DB65-10088C 2-18 Samsung Electronics...
  • Page 25 Product Specifications ■ AC***BNZDCH Item Description Code No. Q’ty Remark CARD WARRANTY 6801-002246 Indoor Unit MANUAL INSTALL Samsung Electronics 2-19...
  • Page 26: Outdoor Unit Accessories

    (AJ036BXJ4CH, AJ048BXJ5CH) DB68-12535A (AJ***CXS*CH) (AJ020BXJ2CH) Nipple Connector DB67-00789A 12.7mm → 9.52mm (AJ024BXJ3CH) (AJ020BXJ2CH) Flare Nuts DB60-30010B 12.7mm → 9.52mm (AJ024BXJ3CH) (AJ****X*4CH) DB96-16155A 12.7mm → 9.52mm (AJ****X*5CH) Ass'y Tube Connector (AJ020CXS3CH, DB96-16155B 12.7mm → 15.88mm AJ****X*4CH, AJ****X*5CH) ※ The design and shape can be changed according to the model. 2-20 Samsung Electronics...
  • Page 27: Disassembly And Reassembly

    Disassembly and Reassembly 3. Disassembly and Reassembly ■ Necessary Tools Item Remark +Screw driver Monkey spanner Samsung Electronics...
  • Page 28: Outdoor Unit

    2) Loosen each 9 screws(CCW) on Cabi-Top. (Use +Screw Driver). 3) Loosen 2 screws(CCW) fixed to assemble Plate Control Out with Cabinet-Side RH. (Use +Screw Driver.) 4) Loosen 10 fixing screws(CCW) on Cabinet- Side RH. (Use +Screw Driver.) Samsung Electronics...
  • Page 29 (Use +Screw Driver.) Ass’y 1) Detach the Motor Wire from the PCB of Control Out Ass'y Control Out. 2) Detach comp wire and pressure switch- wire from the PCB of A’ssy Control Out. 3) Detach 2 Connect Wires from Reactor. Samsung Electronics...
  • Page 30 4) Detach the Heat Exchanger. Befor you disassemble the pipes and Condensor, be sure that there should be no refrgerant remained in the unit. 5) Loosen 3 nuts of the Compressor. (Use Monkey Spanner.) 6) Detach the Compressor. Samsung Electronics...
  • Page 31: Aj036Bxj4Ch

    1) Loosen 6 fixing screws (CCW) on the Cabinet-Side RH. (Use +Screw Driver). Cabi Front RH 1) Loosen 3 fixing screws (CCW) on the Cabinet-Front RH. (Use +Screw Driver). Cabi Top 1) Loosen 7 or 9 fixing screws (CCW) on the Cabi-Top. (Use +Screw Driver). Samsung Electronics...
  • Page 32 Gurad Cond. (Use +Screw Driver). Cabi Back RH 1) Detach the Sensor from the Cabi-Back 2) Loosen 5 fixing screws (CCW) on Cabi- Back RH. (Use +Screw Driver). 3) Pull the hook of Cabi Back RH from the Bracket Valve. Samsung Electronics...
  • Page 33 Parts Procedure Remark Plate Case Control 1) Loosen 2 fixing screws (CCW) on the Plate Support Case Control Support. (Use +Screw Driver). Cabi Front LF 1) Loosen 10 fixing screws (CCW) on the Cabinet-Front LF. (Use +Screw Driver). Samsung Electronics...
  • Page 34 1) Detach the Motor Wire from PCB of A’ssy Control Out. 2) Loosen 4 fixing bolts (CCW) and detach the Motor. (Use +Screw Driver.) Backet Motor 1) Loosen 2 fixing screws (CCW) and detach the Bracket Motor. (Use +Screw Driver.) Samsung Electronics...
  • Page 35 Disassembly and Reassembly Parts Procedure Remark Control Out 1) Detach Comp-Wire and Pressure-Wire from PCB of A’ssy Control Out. 2) Loosen 4 fixing screws (CCW) and detach the Bracket Motor. (Use +Screw Driver.) 3) Separate A’ssy Control Out. Samsung Electronics...
  • Page 36 1) Disassemble the pipes in both inlet and outlet with welding torch. 2) Loosen 2 fixing screws (CCW) and detach the Bracket Valve. (Use +Screw Driver.) Compressor 1) Loosen fixing nut (CCW) on the Cover- Terminal. (Use Monkey Spanner or adjust- able Wrench.) 3-10 Samsung Electronics...
  • Page 37 When assembling Comp Wire, make sure to match the color and location of the wire with the picture. Heat Exchanger 1) Loosen 2 fixing screws(CCW) on both sides. And loosen 1 fixed screws(CCW) Partition with base.(Use +Screw Driver.) Samsung Electronics 3-11...
  • Page 38: Aj048Bxj5Ch, Aj020Cxs3Ch, Aj024Cxs4Ch, Aj030Cxs4Ch, Aj036Cxs4Ch

    2) Remove the 4 screws from the Cabinet Front RH and separate it. (Use + Screw Driver) Cabinet Top 1) Remove the 8 screws which is fixed to each side of cabinet top and separate it. (Use + Screw Driver) 3-12 Samsung Electronics...
  • Page 39 Cabinet Back RH 1) Pull out the sensor from the cabinet back RH and separate it. 2) Remove the 4 screws which is fixed to each side cabinet back RH and separate it. (Use + Screw Driver) Samsung Electronics 3-13...
  • Page 40 Plate Control 1) Remove the 1 screw from the Plate Conrtol and separate it. (Use + Screw Driver) Cabinet Front LH 1) Remove the 10 screws from the canbinet Front LF and separate it. (Use + Screw Driver) 3-14 Samsung Electronics...
  • Page 41 Disassembly and Reassembly Parts Procedure Remark Cabinet Front LH 1) Remove the 2 fixing nuts like the picture on the right side. (Use Hexagon Wrench, Monkey Spanner, Hexagon Socket) Samsung Electronics 3-15...
  • Page 42 Motor. ( Use + Screw Driver ) 3) Separate the Motor Wire connector from the Outdoor Unit Control Part. Bracket Motor 1) Remove the 2 screws from the Bracket Motor and separate it. (Use + Screw Driver) 3-16 Samsung Electronics...
  • Page 43: Troubleshooting

    Error due to connecting outdoor units that do not support the WindFree function : On : Flickering x: Off • If you turn off the air conditioner when the LED is flickering, the LED is also turned off. Samsung Electronics...
  • Page 44 Outdoor valve clogging error Miss matching error between indoor unit and outdoor unit : On : Flickering x: Off - If you turn off the air conditioner when the LED is flickering, the LED is also turned off. Samsung Electronics...
  • Page 45 (Communication error for more than 2 minutes) : On : Flickering x: Off - If you turn off the air conditioner when the LED is flickering, the LED is also turned off. Samsung Electronics...
  • Page 46 EEPROM error E162 EEPROM option error E163 Error due to incompatible indoor unit E164 : On : Flickering x: Off - If you turn off the air conditioner when the LED is flickering, the LED is also turned off. Samsung Electronics...
  • Page 47 2 minutes) : On : Flickering x: Off - If you turn off the air conditioner when the LED is flickering, the LED is also turned off. Samsung Electronics...
  • Page 48: Outdoor Unit

    ERROR ON PIPE IN-C TEMPERATURE SENSOR(SHORT OR OPEN) E333 ERROR ON PIPE IN-D TEMPERATURE SENSOR(SHORT OR OPEN) E334 ERROR ON PIPE IN-E TEMPERATURE SENSOR(SHORT OR OPEN) E335 ERROR ON PIPE OUT-A TEMPERATURE SENSOR(SHORT OR OPEN) E336 ERROR ON PIPE OUT-B TEMPERATURE SENSOR(SHORT OR OPEN) Samsung Electronics...
  • Page 49 ERROR DUE TO INPUT CURRENT SENSOR OF INVERTER PBA(SHORT/OPEN) E488 INCOMING VOLTAGE SENSOR ERROR E500 IPM/PFCM OVERHEAT ERROR E554 THE REFRIGERANT LEAKS COMPLETELY FROM THE OUTDOOR UNIT ERROR DUE TO INDOOR UNIT SOFTWARE VERSION COMBINATION(INCOMPATIBLE INDOOR E563 UNITSOFTWARE ON A SYSTEM) E590 INVERTER EEPROM CHECKSUM ERROR Samsung Electronics...
  • Page 50: Setting An Indoor Unit Address And Installation Option

    • At this point it is possible to start the internal units in the desired mode. ※ If " "doesn’t display, the procedure has failed and it is therefore necessary to read ALL the operator’s NOTE manual before repeating the operating described in steps 1-2-3-4. Samsung Electronics...
  • Page 51 Indication on the display and action to take when an inverter fault is detected. SEG1 SEG2 SEG3 SEG4 Action to take Fault detection is in progress PBA defect: Replace the PBA Check Manual inspection is required Going into fault detection mode failed Try fault detection again Samsung Electronics...
  • Page 52 Outdoor temperature EEV2 current step Running current EEV3 current step Target Discharge temperature EEV4 current step Total capacity of the indoor units Fan RPM (H: high, L: low, Blank: off ) Safety Control (just For Service Technician) 4-10 Samsung Electronics...
  • Page 53: Setting Option

    High Temp button   Fast button Low Temp button   Wind-Free button < AC***BN*DCH / AJ***BNHDCH >  Mode button High Temp button   High Fan button  Low Temp button  Low Fan button Samsung Electronics 4-11...
  • Page 54: The Procedure Of Setting Option

    2 Press ❹ button to enter SEG8. Step 5 Press ❶ button to be changed to FAN mode in the ON status. 1 Press ❺ button to enter SEG9 value. 2 Press ❹ button to enter SEG10 value. 4-12 Samsung Electronics...
  • Page 55 1 Press ❺ button to enter SEG23 value. 2 Press ❹ button to enter SEG24 value. Step 12 Press ❶ button to check whether the option code you entered is correct or not. Press operation button to enter option. Samsung Electronics 4-13...
  • Page 56: Setting An Indoor Unit Address (Main/Rmc)

    • If you set the SEG 9 as 0, the indoor unit will maintain previous RMC ADDRESS even if you input the option value of SEG11~12. 5 The MAIN address is for commnication between the indoor unit and the outdoor unit. Therefore, you must set it to operate the air conditioner properly 4-14 Samsung Electronics...
  • Page 57: Setting An Indoor Unit Installation Option

    Disuse Use(Cooling) Use(Cooling) Reserved Reserved Disuse (Cooling/ Indication Heating) and Details (Cooling/ Heating) Use (Cooling Disuse Ultra low speed) Use (Cooling Ultra low speed) Use (Heating/ Disuse Cooling Ultra low speed)) Use (Heating/ Cooling Ultra low speed) Samsung Electronics 4-15...
  • Page 58 If external drain pump signal is used, external control (SEG14) can't be used. • 3) SEG20 If you set the Individual control with remote control option to a value other than 0 to 4, it is automatically set to 0 (Indoor 1) 4-16 Samsung Electronics...
  • Page 59 Disuse Use(Heating) Use(Heating) Disuse Use(Cooling) Indication Use(Cooling) Reserved Disuse details (Cooling/Heating) (Cooling/Heating) Use (Cooling Ultra compensation Disuse low speed) Use (Cooling Ultra low speed) Use (Heating/ Disuse Cooling Ultra low speed)) Use (Heating/ Cooling Ultra low speed) Samsung Electronics 4-17...
  • Page 60 If you set the Individual control with remote control option to a value other than 0 to 4, it is automatically set to 0 (Indoor 1) • 6) SEG21 Default value of Heating setting compensation is 9°F(5℃). 4-18 Samsung Electronics...
  • Page 61 Disuse Disuse Disuse Disuse Disuse (Heating) (Heating) Disuse (Cooling) Indication (Cooling) Reserved Disuse details (Cooling/Heating) (Cooling/Heating) Disuse (Cooling Ultra low speed) High ceiling mode (Cooling Ultra low speed) Disuse (Cooling Ultra low speed) (Cooling Ultra low speed) Samsung Electronics 4-19...
  • Page 62 Thermo on Use of buzzer hours Disuse Main, On/Off Existing control Reserved Window Indication On/Off and details Disuse Sub, On/Off Reverse control Window Operation Disuse of 2000 On/Off buzzer hours Disuse Main, On/Off Reverse control Window On/Off 4-20 Samsung Electronics...
  • Page 63 Soft Off: The indoor unit turns off its operation at the indicated time in the table for Installation Option after its final motion detection. But, it turns on again if the MDS detects motion. Hard Off: Designated time after SOFT OFF, it cannot turn on automatically when it detects motion. Users should control to turn on the indoor unit with remote control, etc. Samsung Electronics 4-21...
  • Page 64 RESERVED Indication and 2.7°F(1.5°C) 20 minutes Details 5.4°F(3°C) No delay 5.4°F(3°C) 10 minutes 5.4°F(3°C) 20 minutes 8.1°F(4.5°C) No delay 8.1°F(4.5°C) 10 minutes 8.1°F(4.5°C) 20 minutes (Heater 10.8°F(6°C) No delay time delay) 10.8°F(6°C) 10 minutes 10.8°F(6°C) 20 minutes 4-22 Samsung Electronics...
  • Page 65 If you set the Individual control with remote control option to a value other than 0 to 4, it is automatically set to 0 (Indoor 1) • 4) SEG21 Default value of Heating setting compensation is 3.6°F(2℃). Samsung Electronics 4-23...
  • Page 66 Use (Heating/Cooling Disuse Ultra low speed) Use (Heating/Cooling Ultra low speed) Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 Function Page Use of drain pump Indication Details Indication Details Disuse Indication Reserved Reserved Reserved Reserved details external drain pump 4-24 Samsung Electronics...
  • Page 67 If you set the Individual control with remote control option to a value other than 0 to 4, it is automatically set to 0 (Indoor 1) • 6) SEG21 Default value of Heating setting compensation is 9°F(5°C). Samsung Electronics 4-25...
  • Page 68 Disuse Use(Heating) Use(Heating) Disuse Use(Cooling) Reserved Reserved Use(Cooling) Indication Disuse Use (Cooling/Heating) details Use (Cooling/Heating) Use (Cooling Ultra low Disuse speed) Use (Cooling Ultra low speed) Use (Heating/Cooling Disuse Ultra low speed) Use (Heating/Cooling Ultra low speed) 4-26 Samsung Electronics...
  • Page 69 No delay 2.7°F(1.5°C) Reserved minutes Indication 2.7°F(1.5°C) details minutes 5.4°F(3°C) No delay 5.4°F(3°C) minutes 5.4°F(3°C) minutes 8.1°F(4.5°C) No delay 8.1°F(4.5°C) minutes 8.1°F(4.5°C) minutes with 3 (Heater 10.8°F(6°C) No delay minute time delay delay) 10.8°F(6°C) minutes 10.8°F(6°C) minutes Samsung Electronics 4-27...
  • Page 70 If you set the Individual control with remote control option to a value other than 0 to 4, it is automatically set to 0 (Indoor 1) • 4) SEG21 Default value of Heating setting compensation is 3.6°F(2℃). 4-28 Samsung Electronics...
  • Page 71: Changing The Addresses And Option Individually

    CAUTION If you set an indoor unit as the master indoor unit by using the remote control, the outdoor unit automatically operate in the current mode of the master indoor unit. Samsung Electronics 4-29...
  • Page 72: Changing A Particular Option

    Troubleshooting 4-3-6 Changing a particular option Wall Mounted Option Code AR07CSDAFWKN AR09CSDABWKN AR12CSDABWKN AR15CSDAFWKN AR18CSDABWKN AR24CSDABWKN SEG1~6 011A35 011A35 011A35 011A35 011A35 011A35 SEG7~12 17C0E7 17C0E7 17C217 17C227 16C23B 15C29D SEG13~18 271416 271A20 272323 272C38 27353B 273E49 SEG19~24 371449 371449...
  • Page 73 25343B SEG19~24 370040 370000 370000 SEG25~30 020010 020010 020010 SEG31~36 100001 100001 100001 SEG37~42 200000 200000 200000 SEG43~48 300000 300000 300000 SEG49~54 030000 030000 030000 SEG55~60 100000 100000 100000 SEG61~66 200000 200000 200000 SEG67~72 300002 300002 300002 Samsung Electronics 4-31...
  • Page 74 01B3FC-1C5499- 5.0≤P≤7.5 mmAq 271A23-370000 272328-370000 272C34-370000 27343C-370000 01B3FC-1C54D9- 01B3FC-1C54EA- 01B3FC-1C54FB- 01B3FC-1C580C- 7.5≤P≤10.0 mmAq 271A23-370000 272328-370000 272C34-370000 27343C-370000 01B3FC-1C582C- 01B3FC-1C583D- 01B3FC-1C584E- 01B3FC-1C585F- 10.0≤P≤12.5 mmAq 271A23-370000 272328-370000 272C34-370000 27343C-370000 01B3FC-1C5970- 01B3FC-1C5981- 01B3FC-1C5992- 01B3FC-1C59A3- 12.5≤P≤15.0 mmAq 271A23-370000 272328-370000 272C34-370000 27343C-370000 4-32 Samsung Electronics...
  • Page 75 27484F SEG19~24 370000 370000 370000 SEG25~30 020010 020010 020010 SEG31~36 100000 100000 100000 SEG37~42 200000 200000 200000 SEG43~48 300000 300000 300000 SEG49~54 030000 030000 030000 SEG55~60 100000 100000 100000 SEG61~66 200000 200000 200000 SEG67~72 300002 300002 300002 Samsung Electronics 4-33...
  • Page 76: Items To Be Checked First

    The compressor stops intermittently or the fan speed of the COOL mode or DRY mode, and fan speed of the indoor unit decreases to prevent inside/outside air frozen indoor unit decreases. depending on the inside/outside air temperature. 4-34 Samsung Electronics 4-34...
  • Page 77 Troubleshooting ■ If Error code is displayed on indoor or outdoor LED, check as follows; Contents Turn on the system. But outdoor units PCB displayed E201 or E101 Error code. Check point Remarks Check point Remarks Check to power cable to indoor units. Step 1 Wire connect Check to communication cable indoor units.
  • Page 78 Troubleshooting - Address setting another case Contents When the system installation is finished, outdoor unit’s PCB display E202 Error code. Check point Remarks This problem is caused by outdoor unit’s communica- Analysis tion part trouble or indoor units power and communica- The pipe checking operation tion line trouble.
  • Page 79 Troubleshooting - Operation Error Contents While using cooling or heating, indoor units display E161 Error code. Check point Remarks This problem is caused by user’s fault. User’s simultaneously operate 2 more indoor units in the same time cool- Analysis ing and heating mode. FJM is operate by just cooling or heating mode only.
  • Page 80 Troubleshooting Contents While using heating, outdoor unit turn off and display E404 Error code. Check point Remarks Heating overload safety mode make this situation. Analysis After System restart automatically until 3 times, System display this error code and stop. System can operate by remote controller input signal or K3(reset) key input. Step 1 Check indoor units air flow.
  • Page 81: Setting To Cool Or Heat Only Mode, Checking And Cool/Heat Modes Operation Test

    Troubleshooting 4-5 Setting to Cool or Heat only mode, checking and Cool/Heat modes operation test Setting the outdoor option • Press and hold K2 to enter the option setting. (Only available when the operation is stopped) - If you enter the option setting, display will show the following. - Seg 1 and Seg 2 will display the number for selected option.
  • Page 82 This function enables the indoor units connected to the outdoor unit to operate in a specific mode. You can set each mode with Keys on the Main PCB in the outdoor unit. Set mode SEG1 SEG2 SEG3 SEG4 Cooling and Heating Only Cooling Only Heating • Default value: Cooling and Heating mode 4-40 Samsung Electronics...
  • Page 83: Fault Diagnosis By Symptom

    In this case, is the resistance 8.300 value out of range in the temperature 10.00 table on the right? 12.10 Indoor temperature sensor 14.70 failure (replace) 18.00 Restart the system after 22.00 replacing the PCB 28.30 33.90 42.30 Samsung Electronics 4-41...
  • Page 84 PCB? Connect the connector to PCB and restart the unit. Is there foreign substance stuck in the motor fan? Remove the foreign substance and restart the unit. Replace the PCB and restart the unit. 4-42 Samsung Electronics...
  • Page 85 PCB and replace the PCB Reconnect the cable connecting the outdoor unit to the indoor unit and restart the unit. If the communication still doesn’t work, replace the indoor unit PCB. Good +0.7V -0.7V Samsung Electronics 4-43...
  • Page 86 EEPROM component failure, EEPROM circuit parts missing/damaged/soldering failure. Are the EEPROM circuit components in good conditions? (missing components / damage / soldering failure) Replace the PCB if the restart fails Restart the unit after replacing the PCB 4-44 Samsung Electronics...
  • Page 87: Outdoor Unit Is Not Powered On - Initial Diagnosis

    2 (~) and 4 (~) of the bridge diode 220V? Is the fuse connected? Replace the fuse Replace the inverter PBA Is the resistance value of R001 200Ω? Is the reactor connector Connect the reactor. connected correctly? Replace the PBA. Samsung Electronics 4-45...
  • Page 88: Checking Outdoor Controller

    Main control 5V CE159 Voltage 4.75V - 5.25V 4. Checking PFCM Check Resistance between R and S AJ020BXJ2CH, AJ024BXJ3CH AJ***CXS*CH, AJ036BXJ4CH, AJ048BXJ5CH (INVERTER PBA) PFCM PFCM Measuring point Normal value Resistance R - S over the hundreds ㏀ 4-46 Samsung Electronics...
  • Page 89: Outdoor Unit Fan Error

    1V~6V? Replace inverter PCB. Is the fan running the operation mode? Does the voltage between pin6 and pin3 of the fan (CNP901 or CN901) Replace the fan motor. fluctuate? (High 5V~6V, Low:0V~1V) Replace the inverter PCB. Samsung Electronics 4-47...
  • Page 90: Compressor Startup Error, Compressor Lock Error, Compressor Rotation Error

    Is the resistance value Replace the compressor. between the compressor boday and the chassis in the range of Mega Ω Is the compressor connection wire connected to the Check the connection wire. compressor correctly? Replace the outdoor unit Main PCB. 4-48 Samsung Electronics...
  • Page 91: Ipm Over Current Error

    Trun off the power and reconnect the table. value normal? Does the voltage Trun off the power and correct or replace between pin6 and pin3 of the fan (CN901) fluctuate? the temperature sensor location. (High 5V~6V, Low:0V~1V) Replace the inverter PCB. Samsung Electronics 4-49...
  • Page 92: Checking Temperature Sensor

    40°C - 115kohm Connect the sensor to PBA connector supply power and measure the voltage of sensor in the connector. Exchange the Outdoor PBA. Below 0.5V or Over 4.5V? Micom error or connector check. Exchange the Outdoor PBA. Temperature[℃] 4-50 Samsung Electronics...
  • Page 93 40°C - 5.83kohm Connect the sensor to PBA connector supply power and measure the voltage of sensor in the connector. Below 0.5V or Over 4.5V? Exchange the Outdoor PBA. Micom error or connector check. Exchange the Outdoor PBA. Temperature[℃] Samsung Electronics 4-51...
  • Page 94: Pcb Inspection

    The parts should be replaced in the following procedure. The repair is completed. Check the operation of the new part. Replace it with a new part. Detach the faulty part. Check for any faulty part. Set an address. 4-52 Samsung Electronics...
  • Page 95: Pcb Diagram

    PCB Diagram 5. PCB Diagram 5-1 Indoor unit ■ Slim 1 Way, Mini 4Way ▶ This Document can not be used without Samsung’s authorization. Samsung Electronics...
  • Page 96 #1 : COM1(F1) #1 : L- LIVE POWER INPUT #1 : N-NEUTRAL POWER #2 : COM1(F2) OUTPUT #3 : V1(DC12V) #4 : V2(GND) #5 : COM2(F3) #6 : COM2(F4) This Document can not be used without Samsung’s authorization. Samsung Electronics...
  • Page 97 PCB Diagram ■ Slim 1Way (PANEL) ▶ This Document can not be used without Samsung’s authorization. ① CN401-DISPLAY #1: DC12V #2: LED_0 #3: LED_1 #4: LED_2 #5: LED_3 #6: LED_4 #7: - #8: REMOCON Signal Out #9 : PANEL SELECTION...
  • Page 98 PCB Diagram 1. CN101-DISPLAY #1 : 12V #2~6 : LED CONTROL SIGNAL This Document can not be used without Samsung’s authorization.
  • Page 99 #1: DC12V #2: LED_0 #3: LED_1 #4: LED_2 #5: LED_3 #6: LED_4 #7: - #8: REMOCON OUTPUT SIGNAL #9 : PANEL SELECTION #10: REMOCON INPUT SIGNAL #11: GND #12: DC5V #13: - This Document can not be used without Samsung’s authorization.
  • Page 100 PCB Diagram ■ Mini 4Way (PANEL) - This Document can not be used without Samsung’s authorization. 1. CN01-DISPLAY #1 : DC12V #2 : LED_Operation #3 : LED_Defrost #4 : LED_Timer #5 : - #6 : LED_Filter #7 : - #8 : Remocon Signal Out...
  • Page 101 PCB Diagram ■ Home Duct ▶ This Document can not be used without Samsung’s authorization. Samsung Electronics...
  • Page 102 #3~6 : FAN MOTOR SIGNAL CONTROL SIGNAL SIGNAL CONTROL SIGNAL #6 : DC 5V #3 : DC 12V #7~12 : COMMUNICATION #4 : GND SIGNAL #4~6 : COM2 COMMUNICATION SIGNAL This Document can not be used without Samsung’s authorization. Samsung Electronics...
  • Page 103 PCB Diagram ■ Duct S ▶ This Document can not be used without Samsung’s authorization. Samsung Electronics...
  • Page 104 #5 : DISCHARGE SENSOR #6 : GND 17. CN826-FAN MOTOR 18. SH100-EARTH #1 : MOTOR-U PHASE #1 : GND EARTH #2 : MOTOR-V PHASE #3 : MOTOR-W PHASE This Document can not be used without Samsung’s authorization. 5-10 Samsung Electronics...
  • Page 105 PCB Diagram ■ Console ▶ This Document can not be used without Samsung’s authorization. 11 16 19 18 14 4 13 5 12 15 6 Samsung Electronics 5-11...
  • Page 106 17. CN808-EEV 18. CN301-DOWNLOAD 19. CN201-EEPROM PBA CONNECTOR #1~#4:EEV CONTROL SIGNAL →For Developer only,Not available in #1:GND #5,#6:DC12V Actual Site #2:NOT USED →20 Pin Down Loader #3~#7:EEPROM SIGNAL This Document can not be used without Samsung’s authorization. 5-12 Samsung Electronics...
  • Page 107 PCB Diagram ■ MPAH ▶ This Document can not be used without Samsung’s authorization. Samsung Electronics 5-13...
  • Page 108 #1~2 : GND #1~2 : COM1 COMMUNICATION #1 : FLOAT SWITCH SIGNAL SIGNAL #2 : GND #3 : SPI CONTROL SIGNAL #3 : DC 12V #4 : NOT USED #4 : GND #4~6 : COM2 COMMUNICATION SIGNAL 5-14 Samsung Electronics...
  • Page 109: Outdoor Unit

    PCB Diagram 5-2 Outdoor unit ■ AJ020BXJ2CH, AJ024BXJ3CH (INVERTER PBA) ▶ This Document can not be used without Samsung’s authorization. 1. CNP351-MAIN INV 2. CN030-MAIN POWER 3. CN571-ECO DOWNLOAD 4. CNP901-BLDC FAN #1 : RXD #1 : N #1 ~ 4 : ECO DOWNLOAD...
  • Page 110 PCB Diagram ■ AJ020BXJ2CH, AJ024BXJ3CH (MAIN PBA) ▶ This Document can not be used without Samsung’s authorization. 5-16 Samsung Electronics...
  • Page 111 #3 : EEV D SIGNAL #4 : EEV A SIGNAL #4 : EEV B SIGNAL #4 : EEV D SIGNAL #5 : GND #5 : GND #5 : GND This Document can not be used without Samsung’s authorization. Samsung Electronics 5-17...
  • Page 112 PCB Diagram ■ AJ***CXS*CH, AJ036BXJ4CH, AJ048BXJ5CH (INVERTER PBA) ▶ This Document can not be used without Samsung’s authorization. 1. L, N - AC POWER INPUT 2. REACTOR-A1/B1 3. REACTOR-A2/B2 4. CN551 - DOWNLOAD #1 : L - LIVE POWER INPUT /...
  • Page 113 PCB Diagram ■ AJ***CXS*CH, AJ036BXJ4CH, AJ048BXJ5CH (MAIN PBA) ▶ This Document can not be used without Samsung’s authorization. Samsung Electronics 5-19...
  • Page 114 #3 : GND #2 : - #4 : COMP CHECK #4 : DC 5V #3 : N - NEUTRAL POWER #5 : DC 12V OUTPUT #6 : INV POWER CTRL This Document can not be used without Samsung’s authorization. 5-20 Samsung Electronics...
  • Page 115 PCB Diagram ■ AJ***CXS*CH, AJ036BXJ4CH, AJ048BXJ5CH (EMI PBA) - This Document can not be used without Samsung’s authorization. 1. L1 - AC POWER OUTPUT 2. L2 - AC POWER OUTPUT 3. CN01 - AC POWER OUTPUT 4. EARTH #1 : L - RELAY CONTACT...
  • Page 116: Wiring Diagram

    6. Wiring Diagram 6-1 Indoor Unit ■ Slim 1Way, Mini 4Way This Document can not be used without Samsung’s authorization. Samsung Electronics...
  • Page 117 ■ Home Duct This Document can not be used without Samsung’s authorization. Samsung Electronics...
  • Page 118 ■ Duct S Samsung Electronics...
  • Page 119 ■ Console This Document can not be used without Samsung’s authorization. Samsung Electronics...
  • Page 120 ■ MPAH Samsung Electronics...
  • Page 121: Outdoor Unit

    F) at 200k Ω ° ° ※OPTION L1 L2 L1 L2 L1 L2 AC POWER INDOOR-UNIT INDOOR-UNIT USE COPPER SUPPLY WIRES. INPUT POWER COMM UTILISER DES FILS D'ALIMENTATION EN CUIVRE. This Document can not be used without Samsung’s authorization. Samsung Electronics...
  • Page 122 ■ AJ***CXS*CH, AJ036BXJ4CH, AJ048BXJ5CH This Document can not be used without Samsung’s authorization. Samsung Electronics...
  • Page 123: Preference Sheet

    Contact CAUTION your dealer for advice. • Minimum installation height of indoor unit is 0.6 m for floor mounted, 1.8 m for wall, 2.2 m for ceiling. Samsung Electronics...
  • Page 124: Outdoor Unit

    2. Make sure that you put the remote control unit in an area not exposed to direct sunlight, and where there is no source of heat. 3. Make sure that you use the remote control unit in an area away from TVs, audio units, cordlessphones, fluorescent lighting. Samsung Electronics...
  • Page 125: Connecting Up And Purging The Circuit

    (N · m) port cap (Refer to the table) ø 6.35 20 to 25 ø 9.52 20 to 25 10 to 12 ø 12.70 25 to 30 R-140A : Diameter of the screw-1/2-20UNF ø 15.88 30 to 35 Samsung Electronics...
  • Page 126: Refrigerant Refill

    7) Stop operation of the air conditioner. AJ034NCJ5CH, AJ038NCJ5CH 8) Close the 3 way valve, disconnect the pres- sure gauge, and open the 3 way valve again. 9) Close the cap of each valve. Samsung Electronics...
  • Page 127: Refrigerant Adjustment

    Tightening torque Outer diameter (mm) Body cap (N · m) Charging port cap (N · m) ø 6.35 20 to 25 ø 9.52 20 to 25 10 to 12 ø 12.70 25 to 30 ø 15.88 30 to 35 Samsung Electronics...
  • Page 128: Pump Down" Procedure

    6. Make sure you do not bend the connection pipes in the middle and store together with the cables. 7. Move the indoor and outdoor units to a new location. 8. Remove the mountin g plate for the indoor unit and move it to a new location. Samsung Electronics...
  • Page 129: Index Of Model Name

    2016 Europe 2017 (6) Design 2018 Wind-Free, GEO 2019 Wind-Free, AIRISE 2020 2021 AIRISE 2022 2023 (4) Inverter type (7) Series HP, R410A 1st Model HP, R32 2nd Model 7/15K FJM Only Wind-Free Mass North America PM1.0 Wind-Free Samsung Electronics...
  • Page 130 220~240V, 50/60Hz 2023 200~220V, 50Hz 208~230V, 60Hz, 3Φ 220~240V, 50Hz 127V, 50Hz (4) Inverter type 208~230V, 60Hz, 3Φ 380~415, 50/60Hz, 3Φ Indoor unit (NASA) 380~415V, 50Hz, 3Φ Outdoor unit (NASA) Indoor unit (Non NASA) Outdoor unit (Non NASA) Samsung Electronics...
  • Page 131 2021 200~220V, 50Hz 208~230V, 60Hz, 3Φ 2022 220~240V, 50Hz 127V, 50Hz 2023 208~230V, 60Hz, 3Φ 380~415, 50/60Hz, 3Φ 380~415V, 50Hz, 3Φ (4) Product type Indoor unit (NASA) Outdoor unit (NASA) Indoor unit (Non NASA) Outdoor unit (Non NASA) Samsung Electronics...
  • Page 132: Refrigerating Cycle Diagram

    (T_O1) Compressor (Comp) ROOM A Service Valve - Gas Pipe1 (SV_G1) Thermistor - Out 2 (T_O2) ROOM B Service Valve - Gas Pipe2 (SV_G2) Thermistor - Out 3 (T_O3) ROOM C Service Valve - Gas Pipe3 (SV_G3) 7-10 Samsung Electronics...
  • Page 133 ROOM C Service Valve (AC) - Gas Pipe3 (SV_G3) Thermistor - Out 4 (T_O4) Compressor ROOM D Service Valve (Comp) Thermistor - Out 5 - Gas Pipe3 (SV_G4) (T_O5) ROOM E Service Valve - Gas Pipe3 (SV_G5) Samsung Electronics 7-11...
  • Page 134 ROOM B Service Valve Thermistor - Out 3 - Gas Pipe2 (SV_G2) (T_O3) Accmulator ROOM C Service Valve (AC) Thermistor - Out 4 - Gas Pipe3 (SV_G3) (T_O4) Compressor ROOM D Service Valve (Comp) - Gas Pipe3 (SV_G4) 7-12 Samsung Electronics...
  • Page 135 ROOM B Service Valve Thermistor - Out 3 - Gas Pipe2 (SV_G2) (T_O3) Accmulator ROOM C Service Valve (AC) Thermistor - Out 4 - Gas Pipe3 (SV_G3) (T_O4) Compressor ROOM D Service Valve (Comp) - Gas Pipe3 (SV_G4) Samsung Electronics 7-13...
  • Page 136: Pressure & Capacity Mark

    (Full name : Heat exchanger; A device, used to transfer heat from a fluid on one side of a barrier assemble evaporator / to a fluid on the other side without bringing the fluids into direct contact. assemble condenser) 7-14 Samsung Electronics...
  • Page 137: Q & A For Non-Trouble

    Samsung Electronics do not manufacture drain pumps. So, we are not able to correct the drain pump problems. Whenever the air conditioner is turned on, it irritates my eyes and gives me a headache.
  • Page 138 Also, the remote controller may not work under intensive light from a 3-wave length lamp or a neon sign due to the EMI. In this case, take the remote controller closer to the receiver. 7-16 Samsung Electronics...
  • Page 139 There is a cost table. But, our service engineer needs to visit to total up the cost correctly. When you move in, make sure to contact Samsung Electronics Service Center or Authorized Service Agent in advance to streamline the process.
  • Page 140: Common Sense Of Refrigeration

    But generally the value of fresh indoor temperature is that below 0.2(m/s) of indoor air circulation, the temperature is 21~28°C when the wall temperature is the same as the indoor's and relative humidity is 30~31% in summer, the winter temperature is 20~24°C and relative humidity is 30~60% in winter. 7-18 Samsung Electronics...
  • Page 141 Latin America https://gspn6.samsungcsportal.com © Samsung Electronics Co., Ltd. September. 2023. This Service Manual is a property of Samsung Electronics Co., Ltd. Printed in Korea. Any unauthorized use of Manual can be punished under Code No. AC-00261E_3 applicable International and/or domestic law.

Table of Contents