Troubleshooting
Option
SEG13
Explanation
PAGE
ndication
Indication and
Details
2
Option
SEG17
Explanation
Buzzer control
Indication
0
Indication and
Details
1
Option
SEG21
Heating setting
Explanation
compensation
Indication
0
Indication and
1
Details
2
•1) SEG4
By SEG4 setting, Minimizing fan operation when thermostat is off.
- Fan operates for 20 seconds at an interval of 5 minutes in heat mode.
- Fan stops or operates Ultra low in Cooling when thermostat is off.
• 2) SEG18
If you set the Maximum filter usage time option to a value other than 2 and 6, it is automatically set to 2 (1000 hours).
• 3) SEG20
If you set the Individual control with remote control option to a value other than 0 to 4, it is automatically set to 0 (Indoor 1)
• 4) SEG21
Default value of Heating setting compensation is 3.6°F(2℃).
4-20
Use of external control
Details
ndication
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Maximum filter usage time
Details
Indication
Use of buzzer
2
Disuse
6
SEG22
4)
Details
Disuse
RESERVED
3.6°F(2°C)
9°F(5°C)
SEG14
Setting the output of external
Details
ndication
Disuse
On/Off
Sub,
Existing
Off
Control
Window
Disuse
Main,
On/Off
Existing
Off
Control
Window
Disuse
Sub,
On/Off
Reverse
Off
Control
Window
Disuse
Main,
On/Off
Reverse
Off
Control
Window
SEG18
2)
Details
Indication
1000 Hour
2000 Hour
SEG23
Away Set OFF Timer
Indication
0 or 1
2
3
4
SEG15
control
Details
0
Thermo on
Operation
1
on
SEG19
Individual control with remote
PAGE
Details
Indication
0 or 1
3
Details
Auto Set OFF 30Min.
Auto Set OFF 60Min.
Auto Set OFF 120Min.
Auto Set OFF 180Min.
Samsung Electronics
SEG16
RESERVED
SEG20
control
3)
Details
Indoor1
2
Indoor2
3
Indoor3
4
Indoor4
SEG24
RESERVED