Genie DPL Super Series Operator's Manual page 17

Table of Contents

Advertisement

First Edition • Fifth Printing
5 Install each outrigger and adjust the leveling
jacks to level the machine. Level the machine
using only the outriggers. Do not use chocks,
blocks or shims to level the machine.
6 Check the interlock display. Be sure that all four
interlock display lights are on.
7 Use the bubble level and adjust
the leveling jacks until the
machine base is level.
8 Rotate the platform guard
rail locking handle and
rotate the platform side
guard rail to the upright
position. Be sure the side
guard rail locks in place.
Repeat for the other side.
9 Pull the ladder lock pins and rotate the ladder
down. Be sure the ladder locks in place.
10 Climb the ladder to enter the platform. Close and
latch the platform entry gate and the platform
end guard rail.
Part No. 38132
Test Emergency Stop
11 Twist to release the red Emergency Stop button
at the platform controls.
12 Push in the red Emergency Stop button at the
ground controls to the off position.
13 Push in the control
activate button and
rotate the up/down
switch in the direction
of intended travel.
Result: The up/down
function should not
operate.
14 Push in the red Emergency Stop button at the
platform controls to the off position.
15 Pull out the red Emergency Stop button at the
ground controls to the on position.
16 Push in the control activate button and rotate
the up/down switch in the direction of intended
travel.
Result: The up/down function should not
operate.
Genie DPL Super Series
Operator's Manual
FUNCTION TESTS
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dpl-25sDpl-30sDpl-35s