Installation and electrical connection
3.3

Electrical connection

3.3.1
RM-2
In order for the RM-2 to be connected to the power, the eBus cable
(2-pole) must be connected to the terminals of the wall mounted
base. The polarity must be observed. Cable diameter: 0.5...1.5 mm².
Fig. 3.2
eBus terminals (protected against polarity reversal)
q
► Push the terminals with a screwdriver to insert the cable
Once the electricity has been connected, the RM-2 can be placed on
the four fixing hooks of the wall retainer ("put in place and pushed
downwards").
3.3.2

RM-2 Wireless

NOTE
Damage to the appliance
► Only use AAA batteries.
The RM-2 Wireless can be powered in two different ways:
– 3x AAA alkaline batteries (included)
or
– 9 V DC power supply, min. 500 mA; suitable for continuous
operation (not included)
i
3066510_202108
RM-2 terminals (eBus)
Use either batteries or a power supply unit! Using
both at the same time is not permitted and will cause
irreparable damage to the RM-2 Wireless!