Ending charging
b Charging was completed successfully.
Power button lights up white.
Status LEDs light up green.
The display switches on and shows information
about the completed charging process. After a
few minutes, the charger switches to standby
mode.
e
Disconnect the vehicle plug from the vehicle
charge port.
Charging current limiting
The control unit detects the voltage and the availa-
ble current automatically. The charging power to be
used for charging can be set using charging current
limiting. The last charging current set is saved. To
prevent the electrical installation from overheating,
the charging current is automatically limited to 50%
on delivery when domestic electrical outlets are used.
If the charger is connected to an energy manager,
the charging current is limited in line with the val-
ues preset in the energy manager. The maximum
available charging current can also be reduced by
other consumers in the home network, e.g. by an
electric heater or water heater. The charging power
must never be set higher than the maximum available
power of the electrical circuit used. If you are unsure
about this, contact a qualified electrician.
Activating and deactivating ground
monitoring
Electric shock, short cir-
DANGER
cuit, fire, explosion
Use of the charger without active ground monitoring
can cause electric shocks, short circuits, fire, explo-
sions or burns.
e
The charger should preferably be operated in
earthed mains supply systems.
e
Only deactivate ground monitoring in non-
earthed mains supply systems.
e
Activate ground monitoring in earthed mains
supply systems.
g Refer to chapter "Activating ground monitoring" on
page 71.
Deactivating ground monitoring
b An error message indicating an interrupted or
absent protective conductor is shown on the dis-
play.
b Ground monitoring has interrupted the charging
process or prevents it from starting.
Power button lights up red.
Status LEDs light up red.
An error message is shown on the display.
1. To deactivate ground monitoring, acknowledge
the error message with Confirm.
2. Press and hold the Power button
onds.
3. Acknowledge the deactivation of ground moni-
toring with Confirm.
�� Monitoring remains deactivated for subse-
quent charging processes.
Activating ground monitoring
If the charger is operated in an earthed mains supply
system, activate ground monitoring.
1. Open the Ground monitoring menu (Set-
e Ground monitoring).
tings
2. Activate ground monitoring with Activate.
When ground monitoring is activated, the
Ground monitoring menu item will not appear
in the Settings

Logging into the web application

For standard use of the Web Application, select the
Home user type of user. The Customer service user
has additional setting options and is intended for your
Porsche partner for service purposes.
b The access data is to hand.
1. Select the appropriate user in the User field.
2. Enter the password (from the letter containing
access data).
Information
After 25 minutes of inactivity, the user is automati-
cally logged out of the Web Application.
for 3 sec-
menu.