Error Code
Error
E131/F5
FACTORYSETTINGLIB
RARY error.
E132/F5
EASYCOOK data
invalid.
E133/F32
Calibration value error
in the water level
measurement.
E136/F16
Thermostat 160C
defective.
E137/F16
Actuator defective.
827705 REVA
01/2019
Possible Cause
Test/Action
1
2
1
2
Replace the control board.
Replace the thermostat 160C.
High resistance to
1
element, bake element,
2
broil element, or
evaporator element.
56
E Series SO24 (SWS 13543126)
Reload software.
Replace the control board.
Reload software.
Replace the control board.
Check all the element wiring.