Cleaning and maintenance
8 Cleaning and maintenance

8.1 Clean grease collection system

Prerequisite Cooking program has ended

8.2 Function test grease separator

8.3 Function test Automatic flushing

14
Container with 2 liters of warm water is ready.
Sufficient funnel is ready.
Visual inspection
Grease drain hose has a slope to the grease collector.
There is no puddle of grease under the unit.
Remove the grease drain hose from the grease collector.
Hold grease drain hose up and place funnel on top.
Run 2 liters of warm water through the hose.
Cleaning is complete.
Open cooking chamber door.
Remove horde wagon.
Spray water into the cooking chamber with the hand shower for at
least 30 seconds.
Open the relay test in the service menu.
Activate relay K13. The grease pump switches on.
Water/grease is pumped into the collection container = pump
system in order.
Water/grease is not pumped into the collection container = carry
out troubleshooting.
Open the relay test in the service menu.
Activate relay K14.
Solenoid valve K41 for flushing is switched on.
After approx. 30 seconds, additionally activate relay K13.
Water is pumped into the collection tank = solenoid valve OK.
Water and occasional lumps of grease are pumped into the
collection container = clean the grease drainage system. Then
repeat the test.
Water is not pumped into the collection tank = carry out
troubleshooting.
Service-instructions