9.2 Solenoid valve flushing

Switch on solenoid valve K41 via relay test (K14) in
the service menu. After approx. 30 seconds,
additionally switch on grease pump G40 in the relay
test (K13). Is water pumped into the collection tank?
Ensure that water is being supplied on-site. Is this
available?
Are 120V available at the solenoid valve?
Solenoid valve K41 defective. Replace component.
16
Before checking the solenoid valve, make sure that the grease pump
is working properly.
No
Yes
Yes
Service-instructions
Yes
There is no error
No
Carry out troubleshooting on the on-site supply.
No
Relay on control board A1 defective. Use reserve
relay or replace circuit board.