Circulation Blower Assembly

The circulation blower protects the oven from too
much heat inside the oven cavity. It automatically
turns on if it senses too much heat. The blower will
automatically turn off when the internal parts are
cool. It may stay on for 3 minutes or more after the
oven control is turned off.
The circulation motor has an approximate
resistance value of 14 Ω.
Circulation Blower Assembly
To remove the circulation blower assembly:
1.
Remove the oven from cabinet or wall opening
and remove the outer cover. (See
)
.
Partial Removal
2.
Disconnect the 2 wires from the circulation
motor.
3.
Remove wiring from the wire retainer attached
to the left rear of the circulation blower bracket.
3.
Peel back the foam seal from the circulation
blower bracket to expose the 2 wire guide slots.
4.
Remove wiring from the guide slots in the
circulation blower bracket.
Wire Retainer
Foam Seal
Blower Motor Wires
Guide
Slot
5. Remove the single Phillips-head screw that
attaches the fi lter ground wire to the oven
chassis.
6. Remove the 3 Phillips-head screws from the
right side of the circulation motor bracket.
7. Remove the 3 Phillips-head screws from the left
side of the circulation motor bracket.
8. Lift the circulation motor assembly, carefully
move it towards the left side of the oven, then
remove it from the oven.
Oven Removal /
9. Remove the 6 Phillips-head screws that hold the
circulation motor housing to the bracket.
Guide
Slot
Note:
assembly, ensure that the fi lter ground wire is
secured to the oven chassis.
– 36 –
Ground Wire
When installing the circulation blower
(
)
Continued Next Page