GE Advantium 240 Technical Service Manual page 27

Hide thumbs Also See for Advantium 240:
Table of Contents

Advertisement

https://appliancetechmanuals.com
To remove the power board:
1.
Remove the control panel assembly. (See
Panel Assembly
2.
Disconnect wire harnesses from the power
board at locations CN3 and CN21.
3.
Peel back the foam tape and disconnect wire
harness CN101 from the relay board.
4.
Remove the 4 Phillips-head screws that attach
the power board to the control panel bracket.
5.
Lift the power board to clear the retaining tab.
CN101
Foam Tape
.)
CN3
CN21
Tab
To remove the relay board:
1.
Remove the control panel. (See
Control
.)
Assembly
2.
Disconnect the wire harness from the relay
board at locations CN1, CN20, and CN101.
3.
Remove the 5 Phillips-head screws that attach
the relay board to the control panel bracket.
4.
Lift the relay board to clear the 2 retaining tabs.
– 27 –
Control Panel
CN101
CN1
Tab
Tab
CN20

Hide quick links: