Smeg Classica C92IPBL9-1 Translation Of The Original Instructions page 55

Table of Contents

Advertisement

The appliance can work in the following
modes:
• 220-240 V 2~
3 x 10 mm² three-core cable.
• 220-240 V 3~
4 x 6 mm² four-core cable.
• 220-240 V 1N~
3 x 10 mm² three-core cable.
• 380-415 V 2N~
4 x 6 mm² four-core cable.
• 380-415 V 3N~
5 x 4 mm² five-core cable.
The values indicated refer to the
cross-section of the internal
conductor.
Installation
The aforementioned power cables
are sized taking into account the
coincidence factor (in compliance
with standard EN 60335-2-6).
Replacement clamp
In the event of connection to a two- or
three-phase supply, the installed clamp must
be replaced with the one supplied in order
to ensure correct fastening of the cable.
Fixed connection
Fit the power line with an all-pole circuit
breaker in compliance with installation
regulations.
The circuit breaker should be located near
the appliance and in an easily reachable
position.
113

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents