Smeg Classica C92IPBL9-1 Translation Of The Original Instructions page 24

Table of Contents

Advertisement

Controls lock
The controls lock is a device that
protects the appliance from
accidental or inappropriate use.
1. With all cooking zones off,
simultaneously turn the two front right
and rear right cooking zone control
knobs anti-clockwise (position A).
2. Keep them turned until the
appear on the display.
3. Release the knobs.
In order to remove the control lock repeat
the same operations described previously.
If the knobs have been kept turned
to the A position for more than 30
seconds, the following fault
message
display.
After a prolonged period of
interruption to the power supply,
the control lock will be
deactivated. If this is the case, turn
it back on as described above.
Error codes
If the display shows one of the following
error codes
,
Assistance.
82
symbols
appears on the
, contact Technical
Use
Hob power limitation
The induction hob is configured to
operate at 11.1 kW, but it can be
set to operate at 7.4 kW, 4.8 kW
or 3.7 kW.
1. Disconnect the appliance from the mains
power supply and wait 10 seconds
before turning the power back on.
The power level of the hob must be
set within 2 minutes of it being
connected to the mains power
supply.
2. Turn the front left and front right cooking
zone knobs anticlockwise at the same
time (to position "M-A" and "A"
respectively), and keep them in this
position for 3 seconds.
The rear left and rear right cooking zone
displays will indicate "1." and "1".
3. Release the knobs.

Hide quick links:

Advertisement

Table of Contents
loading